9Installation instructions geoTHERM VWS/VWW 0020051574_012.3.2 Component groups - VWWABB A12-30-01ABB A12-30-01L3 L2 L1NPEL3 L2 L1NPEL3 L2 L1NPEL3 L3 L2 L1N NPEL3 L2 L1S SNPEL2 L1L3NABB A8-30-01ABB A8-30-01ABB A8-30-011LLLLL1LNNNNN2N 2 12 1L N2345SCH678 ASBNNAufZuLN1 2 1 21 2 1 21 2 1 2DCF OT AF-+AufZuZHNLZPNL SK2-P NL HK2-PHK2VF2RF1VF1SPBUS DCF/AF EVU 1xZPLP/UV 1ABB A12-30-01564798132Fig. 2.7 VWW - Front view, covers removedKey to Fig. 2.71 Electronic switchbox (see Chap. 5.3)2 Data badge3 Compressor4 Condensate pan5 Fill/drain valve for heat source circuit6 Flow monitor7 Filter drying cartridge8 Evaporator9 Condenserh NoteAs some components of geoTHERM heatpumps (such as the heating circuitpump, 3 way valves or electric auxiliaryheating) are not integrated into the unit,they must be provided by the customerand installed externally.2.4 General notes on operating modes andfunctionsThere are five operating modes available for the heatingcircuit and these can be used for time and temperaturecontrol of the heat pump (see Chap. 8 "Control sys-tem").There are a further three operating modes available forthe combined domestic hot water cylinder.During start-up, you will tell the heat pump which of theconnection configurations listed in the appendix corre-sponds to your installation by entering the number ofthe corresponding hydraulic plan into the controller.Thus all the operating parameters will be set to prede-termined values, so that the heat pump can work opti-mally. However, you can individually set and adapt theoperating modes and functions afterwards.You will find all the information on operating modes,auxiliary and special functions in Chapter 8, "Controlsystem".The heat pump is equipped with numerous automaticauxiliary functions to ensure trouble-free operation(see also Chap. 8.2 "Automatic auxiliary functions"):- Frost protectionPrevents the heating system from freezing- Tank frost protectionPrevents the connected tanks from freezing- Checking the external sensorsChecking the connected sensors during initial commis-sioning using the basic hydraulic circuit that was en-tered previously- Protection against loss of heating waterShuts down when there is a loss of heating water andswitches on again when there is sufficient water pres-sure- Protection against loss of brineShuts down if the brine pressure is too low andswitches on again when the pressure is sufficient- Floor protection circuitOverheating protection for the floor (important forwooden floors)- Pump blocking protectionPrevents seizing of pumps in the system- Freeze protection functionShuts down the compressor if the temperature of theheat source falls below a predetermined valueDescription of the appliance 2