19.1 Checking the aeration setting of the burner.1. The aeration shutter is factory set. It is important to ensurethat the aeration setting is correct (See figure 30).2. If the setting is not as shown in figure 30 adjust the aerationsetting. To do this loosen the two aeration shutter screws,slide the aeration shutter to the desired position and tightenthe screws.19.2 To remove the fascia.1. The bottom of the fascia is held in place with magnets. Holdthe lower outside edges of the fascia and gently pull forward.With the bottom released, lift the fascia upward and clear ofthe upper hanging brackets on the convection box.19.3 To remove the window panel.1. Complete section 19.2.2. The window panel is secured at thebottom with two clamps. To release theclamps, hold at the rear and pull down (Seefigure 31).3. With both clamps released, gently pullthe base of the window panel forward. Holdthe window panel base and lift upward untilclear of the two upper window retainers(See figure 32).4. Replace in the reverse order.19.4 To remove the fuel effect.1. Complete sections 19.3.2. Remove the fuel effect in the reverse order tothat shown for fitting in the ceramic guide. Theceramic fuel effect may cause staining /discolouration to decorative surfaces. It istherefore advisable to protect decorative surfaces.3. Replace in the reverse order.INSTALLER GUIDEFigure 32. Window removalFigure 31. Window panel clampFigure 30. Aerationshutter setting.© Baxi Heating U.K. Limited 2010. Page 37