196 SupplementVEGABAR 82 • 4 … 20 mA/HART46306-EN-1904046 Supplement6.1 Technical dataNote for approved instrumentsThe technical data in the respective safety instructions are valid for approved instruments (e.g. withEx approval). These data can differ from the data listed herein, for example regarding the processconditions or the voltage supply.Electromechanical data - version IP 66/IP 67 and IP 66/IP 68 (0.2 bar)1)Options of the cable entryƲ Cable entry M20 x 1.5; ½ NPTƲ Cable gland M20 x 1.5, ½ NPT (cable ø see below table)Ʋ Blind plug M20 x 1.5; ½ NPTƲ Closing cap ½ NPTMaterial cable gland/Seal insert Cable diameter5 … 9 mm 6 … 12 mm 7 … 12 mm 10 … 14 mmPA/NBR ● ● – ●Brass, nickel-plated/NBR ● ● – –Stainless steel/NBR – – ● –Wire cross-section (spring-loaded terminals)Ʋ Massive wire, stranded wire 0.2 … 2.5 mm² (AWG 24 … 14)Ʋ Stranded wire with end sleeve 0.2 … 1.5 mm² (AWG 24 … 16)Voltage supplyOperating voltage UBƲ Non-Ex instrument 9.6 … 35 V DCƲ Ex-d instrument 9.6 … 35 V DCƲ Ex-ia instrument 9.6 … 30 V DCOperating voltage UB with lighting switched onƲ Non-Ex instrument 16 … 35 V DCƲ Ex-d instrument 16 … 35 V DCƲ Ex-ia instrument 16 … 30 V DCReverse voltage protection IntegratedPermissible residual ripple - Non-Ex, Ex-ia instrumentƲ for UN 12 V DC (9.6 V < UB < 14 V) ≤ 0.7 Veff (16 … 400 Hz)Ʋ for UN 24 V DC (18 V < UB < 35 V) ≤ 1.0 Veff (16 … 400 Hz)Permissible residual ripple - Ex-d-ia instrumentƲ for UN 24 V DC (18 V < UB < 35 V) ≤ 1 Veff (16 … 400 Hz)Load resistorƲ Calculation (UB - Umin)/0.022 A1) IP 66/IP 68 (0.2 bar), only with absolute pressure.