27AquaCoat GM 5000EACWPumpePumpNetzeingangMain powerLufteingangAir inletErdungs-ZylinderGrounding cylinderPrim. 1ATMat. DruckreglerMat. pressure reg. ZerstäuberluftAtomizing airPistoleGun HS-ErzeugerHV-Generator ServiceTyp / Type: VM 5000W85-264 VAC / 47-440 Hz2311001max. 40WJ. WAGNER AGCH - 9450 AltstättenMade in SwitzerlandSerie Nr.:Serial No.:Spannung:Voltage:Artikel Nr.:Article No.:Eingangsleistung:Line Power:Schutzklasse:Protection Class:Norm:Standard: EN 50059IP 54Spannung:Voltage:Strom:Current:max. 18Vppmax. 1,0A28 29 30 31 32 33 34 35 363738 B_03365OPERATING MANUALEDITION 04/2012 PART NO. DOC2321362Connections on the rear side:28 Mains power inputConnection for mains cable with safety clip.29 Primary fuse1.0 ampere slow-acting.30 Gun connectionTo connect a spray gun.31 High voltage connectionConnection for high voltage generator.32 Cover of the service connectionsFor Wagner service personnel only!33 Connection Pump airHose connector ø 10 mm; ø 0.39 inches.34 Connection Material pressure regulatorHose connector ø 8 mm; ø 0.32 inches.35 Connection Earthing switch airHose connector ø 6 mm; ø 0.24 inches.36 Connection atomizing airHose connector ø 8 mm; ø 0.32 inches.37 Compressed air inletHose connector ø 10 mm; ø 0.39 inches.38 Self-locking nut EarthingConnection for the earthing cable (system earth).