22150 cm 3 - 300 cm 3OPERATING MANUALVERSION 05/2015 ORDER NUMBER DOC2340282Description MeasuringunitPump ratio 75:1 55:1 60:1Volume fl ow per double stroke cm3; cc 150 200 240Maximum operating overpressureMPa 53 44 48bar 530 440 480psi 7687 6382 6962Maximum possible strokes in operation /min. 60Maximum recommended strokes per minute incontinuous operation /min. 40Minimum/maximum air inlet pressureMPa 0.25–0.71 0.25–0.80bar 2.5–7.1 2.5–8.0psi 36–103 36–116Compressed air quality: free from oil and waterQuality standard 7.5.4 according to ISO 8573.1, 20107: Particle concentration 5 – 10 mg/m35: Humidity: Pressure dew point ≤ +7 °C4: Oil content ≤ 5 mg/m3Air inlet (inside thread) inch G1"Minimum of the compressed air supply line mm; inch 25; 0.98Air consumption at 0.6 MPa; 6 bar; 87 psi perdouble strokenl 79.9 103.1scf 2.82 3.64Air motor piston diameter mm; inch 220; 8.7 250; 9.8Air motor piston stroke mm; inch 150; 6Sound pressure level at maximum permissible airpressure* dB(A) 83 83Sound pressure level at 0.6 MPa; 6 bar; 87 psi airpressure* dB(A) 81 80Sound pressure level at 0.4 MPa; 4 bar; 58 psi airpressure* dB(A) 69 76Product inlet connection (inside thread) mm G1½"Product outlet (outside thread) mm M24x1.5Weight kg; lb 53; 117 60.5; 133.5Product pH value pH 3.5–9Maximum product pressure at pump inletMPa 2bar 20psi 290Material temperature +5…+80; +41…+176Ambient temperatureConstruction andassembly +5…+50; +41…+122Suspension -20…+60 ; -4…+140Relative humidity % 10–95 (without condensation)Allowable inclination for operation ± 10A rated sound pressure level measured at 1 m distance, LpA1m, according to DIN EN 14462: 2005.Reference measurements have been made by SUVA (Swiss Accident Insurance Institute).5.5.3.1 TECHNICAL DATA FOR JAGUAR AND PROTEC