WAGO-I/O-SYSTEM 750 Device Description 17750-630 SSI Transmitter InterfaceManualVersion 1.2.0, valid from FW/HW-Version 3A/05Pos: 20.11 /Serie 750 (WAGO-I/O-SYSTEM)/Gerätebeschreibung/Anschlüsse/Leistungskontakte/Feldversorgung - Überschrift 3 @ 6\mod_1256294692864_21.docx @ 43664 @ 3 @ 13.2.2 Power Jumper Contacts/Field SupplyPos: 20.12.1 /Serie 750 (WAGO-I/O-SYSTEM)/Wichtige Erläuterungen/Sicherheits- und sonstige Hinweise/Vorsicht/Vorsicht: Verletzungsgefahr durch scharfkantige Messerkontakte! @ 6\mod_1256193279401_21.docx @ 43414 @ @ 1Risk of injury due to sharp-edged blade contacts!The blade contacts are sharp-edged. Handle the I/O module carefully to preventinjury.Pos: 20.12.2 /Serie 750 (WAGO-I/O-SYSTEM)/Gerätebeschreibung/Anschlüsse/Leistungskontakte 2 LK (Messer/Leistungskontakte 2 LK (Messer/Feder) - Einleitung @ 15\mod_1371721641099_21.docx @ 123714 @ @ 1The I/O module 750-630 has 2 self-cleaning power jumper contacts that supplyand transmit power for the field side. The contacts on the left side of the I/Omodule are designed as blade contacts and those on the right side as springcontacts.Pos: 20.12.3 /Serie 750 (WAGO-I/O-SYSTEM)/Gerätebeschreibung/Anschlüsse/Leistungskontakte 2 LK (Messer/Leistungskontakte 2 LK (Messer/Feder) - Abbildung, einfache Breite - Standard @ 15\mod_1367500700037_21.docx @ 118396 @ @ 1Figure 3: Power Jumper ContactsPos: 20.12.4 /Serie 750 (WAGO-I/O-SYSTEM)/Gerätebeschreibung/Anschlüsse/Leistungskontakte 2 LK (Messer/Leistungskontakte 2 LK (Messer/Feder) - Legende @ 15\mod_1371721352500_21.docx @ 123710 @ @ 1Table 5: Legend for Figure “Power Jumper Contacts”Contact Type Function1 Spring contact Potential transmission (Uv) for field supply2 Spring contact Potential transmission (0 V) for field supply3 Blade contact Potential feed-in (0 V) for field supply4 Blade contact Potential feed-in (Uv) for field supplyPos: 20.12.5 /Serie 750 (WAGO-I/O-SYSTEM)/Wichtige Erläuterungen/Sicherheits- und sonstige Hinweise/Achtung/Achtung: Maximaler Strom Leistungskontakte 10 A @ 3\mod_1226499143500_21.docx @ 25029 @ @ 1Do not exceed maximum current via power jumper contacts!The maximum current to flow through the power jumper contacts is 10 A.Greater currents can damage the contacts.When configuring your system, ensure that this current is not exceeded. Ifexceeded, insert an additional supply module.Pos: 20.12.6 /Serie 750 (WAGO-I/O-SYSTEM)/Wichtige Erläuterungen/Sicherheits- und sonstige Hinweise/Hinweis/Hinweis: Potentialeinspeiseklemme für Erde einsetzen! (keine LK für Erde) @ 3\mod_1226499037468_21.docx @ 25023 @ @ 1