WALKY WL1024 Instructions And Warnings For Installation And Use
Also see for WL1024: Instructions and warnings for installation and useQuick start guide
Contents
|
ENEnglish – 1ENGLISHContents1 - WARNINGS AND GENERAL PRECAUTIONS . . . . . . . . . . . . . . . . . . . . 11.1 - Safety warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11.2 - Warnings for installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11.3 - Warnings for use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 - PRODUCT DESCRIPTION AND INTENDED USE . . . . . . . . . . . . . . . . . 13 - INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23.1 - Pre-installation checks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23.2 - Usage limitation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23.3 - Preparatory work prior to installation . . . . . . . . . . . . . . . . . . . . . . . . . . . 23.4 - Installation of the gearmotor mod. WL1024C - WL1024 . . . . . . . . . . . . 33.4.1 - Establishing the length of the gearmotor arm . . . . . . . . . . . . . . 33.4.2 - Installation of a gearmotor with a STANDARD LENGTH ARM . . 33.4.3 - Installation of a gearmotor with a SHORTENED ARM . . . . . . . . 43.5 - Installation of the multi-purpose lamp mod. WLT on the gearmotormodel WL1024C . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43.6 - How to remove the control unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53.7 - Adjusting the alignment of the gate leaves when closed . . . . . . . . . . . . 53.8 - Securing and releasing the gearmotor manually . . . . . . . . . . . . . . . . . . 54 - ELECTRICAL CONNECTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54.1 - Description of the electrical connections . . . . . . . . . . . . . . . . . . . . . . . . 54.2 - Connecting the power cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64.3 - Connecting the gearmotor without a control unit mod. WL1024 . . . . . . 54.4 - Connecting other devices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54.5 - Addressing the connected devices . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64.6 - Initialisation and connection check . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64.7 - Recognition of the connected devices . . . . . . . . . . . . . . . . . . . . . . . . . 64.8 - Recognition of the positions of the mechanical stops . . . . . . . . . . . . . . 64.9 - Gate leaves motion check . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65 - TESTING AND COMMISSIONING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65.1 - Testing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75.2 - Commissioning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 76 - PROGRAMMING THE CONTROL UNIT . . . . . . . . . . . . . . . . . . . . . . . . 76.1 - Level one programming (ON-OFF) . . . . . . . . . . . . . . . . . . . . . . . . . . . . 76.2 - Level two programming (adjustable parameters) . . . . . . . . . . . . . . . . . . 86.3 - Memory deletion . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86.4 - Special functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 87 - WHAT TO DO IF... (troubleshooting guide) . . . . . . . . . . . . . . . . . . . . . . 98 - FURTHER INFORMATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 108.1 - Connection of the OXI radio receiver . . . . . . . . . . . . . . . . . . . . . . . . . . 108.2 - Connection and installation of the back-up battery mod. PS424 . . . . . 108.3 - Connection of the Oview programmer . . . . . . . . . . . . . . . . . . . . . . . . 108.4 - Connection of the Solemyo solar power system . . . . . . . . . . . . . . . . . 109 - PRODUCT MAINTENANCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10DISPOSING OF THE PRODUCT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11PRODUCT TECHNICAL SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . 11Product life span . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12EC DECLARATION OF CONFORMITY . . . . . . . . . . . . . . . . . . . . . . . . . . . 12APPENDIX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IInstructions and warnings for the user . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IIIImages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . X1.1 - Safety warnings• IMPORTANT! – This manual contains important instructions and warn-ings regarding safety. Incorrect installation may cause serious injury. Beforecommencing work, all sections of the manual must be read carefully. If in anydoubt, suspend installation and call the Nice Support Service for clarification.• IMPORTANT! – This manual contains important instructions. Keep it forfuture maintenance work and disposal of the product.• IMPORTANT! – Under the latest European legislation, automatic doorand gate installations must be compliant with the standards specified inDirective 2006/42/EC (formerly 98/37/EC) (the Machinery Directive) andthe standards EN 12445, EN 12453, EN 12635 and EN 13241-1 in partic-ular, which enable conformity of the automated functionality to be de-clared. In the light of the above, all work involving installation, con-nection, testing and maintenance of the product must be carried outexclusively by qualified and competent technicians!1.2 - Warnings for installation• Before commencing the installation, check if the product is suitable for thedesired type of use (see “Usage limitation” paragraph 3.2 and the "Producttechnical specifications”). If it is not suitable, DO NOT continue with the instal-lation.• All installation and maintenance work must be carried out with the au-tomation system disconnected from the electricity supply. If the powerdisconnection device cannot be seen from where the automation system ispositioned, then before starting work a notice must be attached to the dis-connection device bearing the words “CAUTION! MAINTENANCE IN PRO-GRESS”.• The Control unit must be connected to an electricity supply line equippedwith protective earthing.• Handle the product with care during installation, taking care to avoid crush-ing, denting or dropping it, or contact with liquids of any kind. Keep the prod-uct away from sources of heat and naked flames. Failure to observe theabove can damage the product, and increase the risk of danger or malfunc-tion. Should this occur, suspend installation work immediately and contactthe Nice Support Service.• Do not modify any part of the product. Prohibited modifications can only leadto malfunctions. The manufacturer declines all responsibility for damage re-sulting from unauthorized changes made to the product.• If the gate or door being automated has a pedestrian gate, then the systemmust include a control device that will inhibit the operation of the motor whenthe pedestrian gate is open.• The product’s packaging material must be disposed of in full compliance withlocal regulations.1.3 - Warnings for use• The product is not intended for use by persons, including children, with limit-ed physical, sensory or mental capacities, or who lack experience or knowl-edge, unless supervised or trained in the use of the product by a personresponsible for their safety.• Any children near the automation system must be kept under supervision toensure that they do not play with it.• Do not allow children to play with the fixed control devices. Keep remote con-trol devices out of the reach of children.WARNINGS AND GENERAL PRECAUTIONS1The devices comprising this product are designed to automate a gate or doorwith one or two leaves. IMPORTANT! – Any other use apart from thatdescribed herein, including in different environmental conditions fromthose described in this manual is to be considered improper use and isnot permitted!The principal component of the automation system comprises one or two elec-tric gearmotors (according to the number of leaves to be automated), eachequipped with a direct current motor and epicyclic reduction gear. One of thegearmotors (mod. WL1024C) has a control unit that controls its operation. TheControl unit consists of a board with a radio receiver for receiving the com-mands sent by the transmitter.The control unit is designed for connection to several devices belonging to theOpera system, the Bluebus system and the Solemyo solar powered system.If it is mains powered, it can house a back-up battery (mod. PS424, optionalaccessory) which in the event of a power cut (electricity black-out) guaranteesthat the automated device will perform certain manoeuvres in the hours that fol-low.In the event of a power cut, the gate leaves can be moved by releasing thegearmotor with the dedicated key; to perform the manoeuvre manually pleasesee chapter 3.8.PRODUCT DESCRIPTION ANDINTENDED USE2 |
manualsdatabase
Your AI-powered manual search engine