9InstallationClearancesNOTE: Only non-combustible materials can be used in close proximity to this appliance.* Side clearances can be 50 mm when the adjacent surface is at least 100 mm below the cookingsurface.AssemblyNOTE:• All Models are delivered completely assembled. No further assembly is required.• This appliance is fitted with adjustable feet to enable the appliance to be positionedsecurely and level. This should be carried out on completion of the gas connection. Referto the ‘Gas Connection’ section.Optional Accessories (Refer to Replacement Parts List)• Rear Roller Kit. For installation details, refer to the instructions supplied with each kit.• Plinth Kit. For installation details, refer to the instructions supplied with each kit.1. Check that all the feet (or castors) are securely fitted.2. Adjust the four feet to make the Range steady and level.Gas ConnectionNOTE: ALL GAS FITTING MUST ONLY BE CARRIED OUT BY AN QUALIFIED PERSON.1. Waldorf Gas Range Static Ovens do not require an electrical connection, as they function totally onthe gas supply only.2. It is essential that the gas supply is correct for the appliance to be installed and that adequatesupply pressure and volume are available. The following checks should therefore be made beforeinstallation:-a. Gas Type the appliance has been supplied for, is shownon coloured stickers located above the gas connectionpoint and rating plate. Check that this is correct for thegas supply the appliance is being installed for. The gasconversion procedure is detailed in this manual.b. Supply Pressure required for this appliance is shown inthe “Specifications” section of this manual. Check the gassupply to ensure adequate supply pressure exists.c. Input Rate of this appliance is stated on the Rating Plateand in the ‘Specifications’ section of this manual. The inputrate should be checked against the available gas supplyline capacity. Particular note should be taken if theappliance is being added to an existing installation.NOTE: It is important that adequately sized piping runs directly to the connection joint on theappliance with as few tees and elbows as possible to give maximum supply volume.3. Fit the gas regulator supplied, into the gas supply line as close to the appliance as possible.NOTE: The gas pressure regulator provided with this appliance is convertible between Natural Gasand LPG as per the ‘Gas Conversion Section’ in this manual.Ensure the regulator is converted to the correct gas type that the appliance will operate on.The regulator outlet pressure is fixed ex-factory for the gas type that theregulator is converted to and it is NOT to be adjusted.Fig 1Rating Plate will belocated in this AreaCombustible Surface Non Combustible SurfaceLeft/Right hand side 250 mm (*) 0 mmRear 100 mm 0 mm