14OperationLighting the Oven Pilot BurnerThis oven is fitted with a pilot as a standard option and flamefailure protection, which is incorporated by way of athermo-electric system for the main burner. Flame failureprotection will shut off the gas supply to the burner in theevent that the pilot burner goes out, so that un-burnt gas is notexpelled.This is an important safety feature which isslowly becoming law throughout the world.1. Open the oven door. Partially depress the thermostatcontrol knob whilst turning anti-clockwise to the ‘Pilot’position. DO NOT fully depress the Control Knobwhilst trying to rotate anti-clockwise as the Knoband Gas Valve will be damaged.2. With the thermostat control knob in the ‘Pilot’ position,keep the knob depressed whilst pressing the piezo igniterbutton. (Each press of the piezo igniter button willgenerate a single spark).3. Hold in the thermostat control knob depressed forapprox. 10-20 seconds, then release. The pilot burnershould remain alight. (If the pilot does not light, repeatItems 1 to 3 above).4. View the oven pilot burner through the holes in the frontof the sole plate with the oven door open.Lighting the Oven Main Burner1. Ensure that the pilot burner is alight.2. Rotate the thermostat control knob anti-clockwise to thedesired temperature marked on the knob.3. The main burner will now ignite automatically, from thepilot burner.Turning the Oven to ‘Stand-by’ (Pilot ‘ON’ Only)NOTE: DO NOT attempt to rotate the Thermostat ControlKnob anti-clockwise back to the ‘Pilot’ position asthe Knob and Gas Valve will be damaged.1. Rotate the thermostat control knob clockwise to the‘Pilot’ position. The main burner will extinguish andthe pilot burner will remain alight.Pilot Burnerviewing holesFig 4DO NOT USE aluminium foil or trays directly on the castiron sole plate(s). NEVER block or cover the openings oneach side of the sole plate(s).! IMPORTANTControl Knob inPilot PositionDepress and Rotate KnobAnti-Clockwise to Pilot PositionPiezo IgniterButtonControl Knob in MainBurner Operating PositionRotate Knob Anti-Clockwiseto Operating TemperatureControl Knob inPilot PositionRotate Knob Clockwise to Pilot PositionPiezo IgniterButton