6The electrical installation of your Wallbox must be performed by a qualified electrician in accordance with the applicable normsand standards. You must consider the local electrical installation regulations, fire prevention measures and accident preventionregulations as well as emergency routes at this site.PRECAUTIONSTake special care while selecting the mounting surface, it has to be constructed in order to withstand your Wallbox weightand the mechanical forces associated with the charging process.The power supply connection must comply with the standards and regulations for cabling and building infrastructure.The Wallbox device must be connected through a permanent grounded conductor of the power supply system.Before installing or cleaning your Wallbox ensure that the power supply is turned off and the system has not energy.Sufficient air circulation must be ensured at the mounting site so that the charging station is cooled during operation:Always observe the allowed operating temperatures of the device.Do not install the Wallbox charger nearby:x Flammable, explosive or combustible materials.x Chemicals or solvents.x Flood prone areas, water passage areas or humid environments.x Gas conductors or vapor outlets.x Accumulators, storage radiators or heat emitting elements.x Direct Sunlight radiation, so as to avoid overheating and degradation over time.INSTALLATION INSTRUCTIONSOutdoors installation: The charging station should only be installed in covered locations that provide sufficientprotection from rainwater.Installation in a garage or carport is recommended, as long as it fulfills the stated requirementsPlease contact an electrician or arrange installation at your premises with your local distributorELECTRICAL PROTECTIONSThe power supply line must be hardwired to an existing installation and according to your local regulations.The charger must be electrically protected installing externally a Miniature Circuit Breaker (MCB) and a Residual CircuitBreaker (RCD).• MCB: maximum value according to the maximum output current of the charge point.• RCD of at least type A (30 mA triggering current) for single phase and type B for three phase.Recommended protections, take also into account the local regulations