Contents - Table Of Contents
- Table Of Contents
- Table Of Contents
- Declaration of conformity
- Warranty
- Exceptions
- When you unpack your pump
- Optional accessories
- Information for returning pumps
- Safety notes
- Pump specifications
- Standards (AC mains power supply)
- Standards (12-24V DC power supply)
- Dimensions
- Weights
- Good pump installation practice
- Do's and do not's
- Connecting to a power supply
- DC power supply option
- Start-up check list
- Automatic control wiring - Universal, Universal+ and Remote models without relay modules
- Input pin assignments at the pump
- Output pin assignments at the pump
- Optional output lead
- Module: cover removal and refitting
- Wiring up the terminal connectors
- V relay module pcb connectors
- V relay module pcb connectors
- PROFIBUS control wiring
- Pin assignments at the pump
- Switching on (Manual, PROFIBUS, Universal and Universal+)
- Switching the pump on in subsequent power cycles (Manual, PROFIBUS Universal and Universal+ only)
- Switching on (Remote)
- Pump operation
- Manual mode (Manual, PROFIBUS, Universal and Universal+ only)
- PROFIBUS mode(PROFIBUS only)
- Assigning the PROFIBUS station address at the pump
- PROFIBUS communication errors
- PROFIBUS GSD file
- User Parameter Data
- PROFIBUS data exchange
- Device-related diagnostic data
- Flow calibration mode (Manual, PROFIBUS, Universal and Universal+ only)
- Analog 4-20mA mode (Universal and Universal+ only)
- Calibrate the pump for 4-20mA control (Universal+ only)
- Contact Mode (All Universal and Universal+ models except 110V relay versions)
- Contact operating mode (All Universal and Universal+ models except 110V relay versions)
- Fluid recovery mode (Manual, PROFIBUS, Universal and Universal+ only)
- Remote fluid recovery (Universal and Universal+ models without relay modules)
- Main menu (Manual, PROFIBUS, Universal and Universal+ only)
- Fluid level monitor (Manual, PROFIBUS, Universal and Universal+ only)
- Security settings (Manual, PROFIBUS, Universal and Universal+ only)
- General settings (Manual, PROFIBUS, Universal and Universal+ only)
- MODE menu (Manual, PROFIBUS, Universal and Universal+ only)
- Control settings (Manual, PROFIBUS, Universal and Universal+ only)
- Help (Manual, PROFIBUS, Universal and Universal+ only)
- Status LEDs (Remote only)
- Troubleshooting
- Error codes
- Error Indication (Remote only)
- Technical support
- Drive maintenance
- Connecting interface tubing
- Ordering information
- Spares and accessories
- Performance data
- Performance curves
- Trademarks
- Publication history
|
7 Good pump installation practice7.1 General recommendationsAlways consult an expert before installing a metering pump in aspecialised system. Metering pumps should be maintained byqualified persons.The pump must be bolted to a flat, horizontal, rigid surface, free from excessive vibration,to ensure correct lubrication of the gearbox and correct pumphead operation. Allow a freeflow of air around the pump to ensure that heat can be dissipated. Ensure that the ambienttemperature around the pump does not exceed 45°C (113°F).The STOP key on pumps supplied with a keypad will always stop the pump. However, it isrecommended that a suitable local emergency stop device is fitted into the mains supply tothe pump.Do not stack pumps.This pump is self-priming and self-sealing against backflow. No valves are required in inletor discharge lines, except as described below. Valves in the process flow must be openedbefore the pump operates.Users must fit a non-return valve between the pump and thedischarge pipework to avoid the sudden release of pressurised fluidin the event of a pumphead failure. This shall be fitted immediatelyafter the discharge of the pump.qdos is a positive displacement pump; therefore, it is recommendedbest practice that customers incorporate discharge pressure relief intheir piping system. Failure to fit a pressure release valve in thedischarge pipework will result in excessive build up of pressureshould the discharge become blocked. This may present a safety risk,may cause damage to the system pipework or lead to prematurefailure of the pumphead. The pressure relief valve shall be rated at nomore than 10 bar. It shall always be rated at below the users systemmaximum operating pressure. It shall be installed so as to provideeasy access for maintenance, inspection and repair. It shall not becapable of being adjusted without the use of a tool. The dischargeopening must be located and directed so that the release material isnot directed towards any person and will not deposit on parts thatcould cause a hazard. There must not be a shut-off valve between theoverpressure safety device and the pump.Do not block the drain port of the ReNu pumphead.Ensure the chemicals to be pumped are compatible with thepumphead and the pipework and fittings to be used with the pump.Please refer to the chemical compatibility guide which can be found at:www.wmftg.com/chemical. If you need to use the pump with anyother chemical please contact Watson-Marlow to confirm compatibility.m-qdos-en-02 20