18 193.2.3 Water floor heating (only 1 BT-M6Z02 RF).Equipments:• 1 Connecting Box BT-M6Z02 RF• 1 Thermostat BT-D02 RF (or BT-A02 RF or BT-DP02 RF)For a correct installation, refer to dedicated user guides of each product, then:WIRING CONNECTION:• Connect the actuators (eg. 22C – 22CX series) to the connecting boxBT-M6Z02 RF• Connect the circulating pump to the connecting box BT-M6Z02 RF• Connect the connecting box BT-M6Z02 RF to the heating relay of the boilerVIRTUAL – RF CONNECTION:1 Pair each thermostat to each zone of the BT-M6Z02 RF.One thermostat can drive several zonesBT-D02 RF? UP TO SIXBT-M6Z02 RF21For a correct installation, refer to dedicated user guides of each product, then:WIRING CONNECTION:• Connect the actuators (eg. 22C – 22CX series) to the connecting box BT-M6Z02 RF• Connect the circulating pump to the connecting box BT-M6Z02 RF• Connect the connecting box BT-M6Z02 RF to the heating relay of the boilerVIRTUAL – RF CONNECTION:1 Pair each thermostat to each zone of the BT-M6Z02 RF. One thermostat can driveseveral zones