White Rodgers ComfortPlus HSP2000 Installation Instructions Manual
Contents |
10 11The Humidifier Automatic Flushing Timerautomatically flushes accumulated min-eral deposits from all central-systemsteam- and reservoir-type humidifiers.This enables homeowners to enjoy thebenefits of healthful, humidified air withoutthe hassles of frequent maintenance dueto mineral buildup.The flushing timer is set at the factoryto flush the humidifier every two hoursfor a duration of 10 seconds, usingonly about 1.5 gallons of water per day.(See “To Reprogram the Automatic Flushing Timer”, pages 11 and 12, foralternate settings.) This flushing reduces or eliminates servicing during thehumidification season, depending on the mineral content of the water.How To Install theProgrammable Automatic Flushing TimerTo Install the Flushing Timer on a Steam Humidifier:Locate a suitable waste drain for disposal of flushed water.CAUTION: Drain tubing must not kink or come in contact withsharp edges or hot surfaces. Tubing must run in a continual down-hill slope to allow proper drainage and to prevent overflow.4a. If this flushing timer was purchased as an accessory to install on asteam humidifier... remove the drain valve from the humidifier andinstall the 90º barbed fitting (provided). (See Figure 9 on page 10.)4b. If this flushing timer was purchased with the steam humidifier as acomplete assembly... the 90º barbed fitting should already be installedon the humidifier in the proper location. (See Figure 9 on page 10.)Screw the unit to the mounting surface selected in Step #2.Cut a piece of drain tubing to reach from the humidifier fitting to the fittingon the side of the flushing timer.CAUTION: Drain tubing must not kink or come in contact with sharpedges or hot surfaces. (This caution applies to step #7, as well.)Cut a second piece of tubing to reach from the bottom fitting on theflushing timer to the drain. (See Step #3.)Connect tubing with clamps or fittings suitable for your installation.Return the steam humidifier to its normal operating mode. Refer to pages8 & 9 to properly set the water level.Plug the flushing timer into the designated outlet. (See Step #2.)Check all fittings for leaks. Tighten as necessary.Test the flushing timer for proper operation.Press and release the MANUAL button.Wait 10 to 30 seconds* until the flushing noise stops, indicating thatthe flushing cycle is complete.*The number of seconds will vary depending upon how the unit isprogrammed. (See “To Reprogram the Automatic Flushing Timer”,below.)To Reprogram the Automatic Flushing Timer:The flushing timer is set at the factory to flush the humidifier every two hoursfor a duration of 10 seconds, using approximately 1.5 gallons of water perday. Although the two-hour intervals between flushes may not be altered, theduration may be lengthened to either 20 or 30 seconds per flush.Unplug the flushing timer from the electrical outlet.Take off the back cover plate by removing the three screws closest tothe mounting flanges..5.6.7.8.9.10.11.12.A.B.1.2.Figure 9—Installation of aProgrammable AutomaticFlushing Timer on a SteamHumidifierCAUTION: All plumb-ing and electrical con-nections must complywith relevant codes andordinances.If the humidifier hasbeen preinstalled andneeds servicing, referto “How to Maintain aWhite-Rodgers Com-fortPlus Humidifier”(page 12) for instructions.For either a new or preinstalled humidifier, select a suitable mountinglocations for the flushing timer within 3 feet of the humidifier, and within10 feet of a properly fused electrical outlet.1.2. |
Related manuals for White Rodgers ComfortPlus HSP2000
This manual is suitable for:
manualsdatabase
Your AI-powered manual search engine