Bistro Installation and Operation ManualQuestions? Call Wood Stone at 1-800-578-6836 18May2008The incoming gas supply pressure must not exceed 1/2 psi (14 inches WC). If theincoming gas pressure exceeds 1/2 psi, an external gas regulator must be installedin the supply line. If the supply pressure is less than 1/2 psi, no external regulator isrequired.The installer should bleed any air out of the gas line supplying the appliance. All gasconnections and fittings on the appliance should be leak checked with an approvedsoap solution.13. Checking the burner manifold pressure. The burner manifold pressure has been setat the factory, however it should be checked by the installer. The pressure should bechecked at the outlet tap on the Honeywell gas valve, located on the back of the controlbox. Once the manometer is connected, turn the appliance on and use the flame heightknob to adjust the flame to its maximum height. Then check the manifold pressure.Natural Gas (NG) 4355, 4343 and 3030 Models- 4.5" WC,Propane (LP) 3030 models-7 "WC, Propane (LP) 4355, 4343 Models-9" WCThis information can also be found on the data plate located on the rear of the controlbox.14. Install the rear panel, front panel, and toe kick using the 1/4-20 screws provided.The front panel must not be covered so as to allow access for service to the burner,gas, and electrical components. The appliance should be bolted to the floor using theholes provided at the base of the stand.ASSEMBLY-CONNECTIONSThe installation must conform with local codes, or in the absence of local codeswith the National Fuel Gas Code, ANSI 223.1, Natural Gas Installation Code, CAN/CGA-B149.1, as applicable. The appliance and its individual shutoff valve must bedisconnected from the gas supply piping system during any pressure testing of thatsystem at test pressures in excess of 1/2 psi. The appliance must be isolated fromthe gas supply piping system by closing its individual manual shutoff valve during anypressure testing of the gas supply system at test pressures equal to or less than 1/2psi.