PhaserMatch and PhaserCal 4.0 User Guide2-1.Spectrophotometer-Based CalibrationThere are two methods provided for entering the calibration data values measured by aspectrophotometer. The first method allows you to use PhaserMatch or PhaserCal software tocontrol and communicate with a spectrophotometer that is connected to your computer. Thesecond method allows you to manually import LAB measured data.The spectrophotometers that can be controlled by PhaserMatch or PhaserCal software are:■ GretagMacbeth Spectrolino/SpectroScan■ GretagMacbeth Eye-One System■ X-Rite DTP-41■ X-Rite DTP-70■ X-Rite PULSE■ X-Rite Digital Swatchbook■ SpectroStar SpectroCamNote: PhaserMatch and PhaserCal software do not support any densitometers for performinga color calibration procedure.PhaserMatch and PhaserCal software walks you through a series of steps that generate anddownload the calibration data to a printer.To perform a spectrophotometer-based calibration:1. Launch the PhaserMatch or PhaserCal application.2. Click the Calibrate Printer button in the main screen.3. Click the Spectrophotometer-Based Calibration button in the main Calibrate Printerscreen4. Select a device from the list of supported spectrophotometers or select Manually EnterData.5. Select a printer, print quality, and paper type you use to do the calibration procedure.Printer Calibration