IPv6Phaser® 4510 Laser Printer2-18Manual Address AssignmentEnter an IPv6 address manually to add it to any other IPv6 addresses. To create a manualaddress, enter the IPv6 address and prefix length in the fields provided in CentreWare IS. Thedefault prefix length is 64.To manually set the IPv6 address, use one of the following options:■ The printer’s control panel■ CentreWare ISSetting the IPv6 Address with the Control PanelTo set the IPv6 address on the control panel:1. Select Printer Setup, and then press the OK button.2. Select Connection Setup, and then press the OK button.3. Select Network Setup, and then press the OK button.4. Select TCP/IPv6 Setup, and then press the OK button.5. Select Manual Address, and then press the OK button to turn manual addressing on.6. Select Manual Address, and then press the OK button.7. To set the address:a. Press the Up Arrow and Down Arrow buttons to set the first number, and then pressthe OK button.b. Continue setting individual numbers; press the OK button after each selection. Whenyou are finished adding numbers for the address, press the OK button to return to themenu.Setting the IPv6 Address Using CentreWare ISTo manually set the IPv6 address using CentreWare IS:1. Launch your web browser.2. Enter your printer’s IP address in the browser’s Address field.3. Click Properties.4. Select the Protocols folder on the left navigation panel, and then click TCP/IP.5. Click the TCP/IP (v6) button.6. In the Manual Address Assignment field, select Use this address, and then type theaddress.7. Click the Save Changes button at the bottom of the page.Downloaded From ManualsPrinter.com Manuals