Word componentaddressModbus address( decimal K )Modbus address( hex H )D0~D7999 0~7999 0~1F3FTD0~TD618 12288~12906 3000~326ACD0~CD634 14336~14970 3800~3A7AD8000~D8511 16384~16895 4000~41FFFD0~FD5000 18432~23432 4800~5B88FD8000~FD8511 26624~27135 6800~69FFFree format communication transfer data in the format of data block, each block can transfer 128bytes at most. Meanwhile each block can set a start symbol and a end symbol, or not set.When communicating in free format mode, FD8220 should be 255.3B 4. HMI function and using4-1 HMI functionThe HMI part of XMP2-32 series product is integrated with MP-760T touch screen.The faceplate key-presses are as below:Key FunctionRunning the program, LED indication lightStop running the program, LED indication lightWhatever the mode of the display is in, it will return to original systemscreen once you press the key ( the defaulted screen is No.1 ). Generally, setthe original system screen to be main menu or most used screen.Turn the screen to the last pageFree format communicationStart Symbol (1 byte) Data Block (max bytes 128 ) End Symbol (1 byte)