9 Output Assemblies (Drive Consumes)YASKAWA ELECTRIC SIEP C730600 28B V1000 Option SI-N3/V Technical Manual 41 Speed Command 2 (Vendor Specific YE Assy) - 122 (0x7A)Output Instance Byte Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 01220 –Multi-FunctionInput 7 <1>Multi-FunctionInput 6Multi-FunctionInput 5Multi-FunctionInput 4Multi-FunctionInput 3RunRevRunFwd1 – – – – – – FaultResetExternalFault2 Speed Reference (Low Byte)3 Speed Reference (High Byte)4 NetRef5 NetCtrlParameter DataRun FwdForward Run Command0: Stop1: Forward RunRun RevReverse Run Command0: Stop1: Reverse RunMulti-Function Input 3Terminal S3 Function Input0: Terminal S3 Function (H1-03) OFF1: Terminal S3 Function (H1-03) ONMulti-Function Input 4Terminal S4 Function Input0: Terminal S4 Function (H1-04) OFF1: Terminal S4 Function (H1-04) ONMulti-Function Input 5Terminal S5 Function Input0: Terminal S5 Function (H1-05) OFF1: Terminal S5 Function (H1-05) ONMulti-Function Input 6Terminal S6 Function Input0: Terminal S6 Function (H1-06) OFF1: Terminal S6 Function (H1-06) ONMulti-Function Input 7 <1><1> CIMR-VC drives do not have terminal S7.Terminal S7 Function Input0: Terminal S7 Function (H1-07) OFF1: Terminal S7 Function (H1-07) ONExternal FaultExternal Fault EF00: No External Fault (EF0)1: External Fault (EF0)Fault ResetFault Reset0: No Fault Reset1: Fault ResetSpeed ReferenceSpeed CommandSets drive speed referenceUnit depends on o1-03.Unit is not affected by Speed Scale SS.NetRefSpeed reference form Network0x00: Depends on b1-010x01: Enables the speed reference from networkNetCtrlRun command form Network0x00: Depends on b1-020x01: Enables the run command from network