VX-127 OPERATING MANUAL48EMERGENCY AUTOMATIC ID (EAI) FEATUREThe Emergency Automatic ID (EAI) Feature requires that you (1) store the CTCSS TonePair into the Receiving Pager Memory (see page 26 for procedure), and (2) store the desiredcoordination frequency into Memory Channel “200” (see page 29 for procedure).To enable this feature:1. Press the [SET( )EMG] key momentarily to enter the Set mode.2. Rotate the DIAL knob to select Set Mode Item 53: EAI.3. Press the [F] key momentarily to enable adjustment of this SetMode Item.4. Rotate the DIAL knob to select the desired EAI mode (INTtervalEAI or CONtinuous EAI) and its transmit time (1-10, 15, 20,30, 40, and 50 minutes) or OFF.5. Press the PTT switch to save the new setting and exit to normal operation.6. To disable the Emergency Automatic ID feature, just repeat the above procedure, ro-tating the DIAL knob to select “OFF” in step 4 above.When the Emergency Automatic ID feature is activated, the “ ”icon will blink in the LCD.The VX-127 will ignore the EAI feature when the (1) the squelch is open, (2)there is an incoming the signal on the operating frequency, or (3) the operat-ing frequency is the same as the frequency which is stored in the MemoryChannel “200.”EMERGENCY FEATURE