VX-127 OPERATING MANUAL74Set Mode Item 1 [APO]Function: Setting of the Automatic Power-Off feature.Available Values: OFF/0.5H - 12.0 H in 0.5 hour multiplesDefault: OFFSet Mode Item 2 [ARTS]Function: Selects the Beep option during ARTS operation.Available Values: INRANG/ALWAYS/OFFDefault: INRANGINRANG: Beeps sound only when the radio first detects that you are within range.ALWAYS: Beeps sound every time a polling transmission is received from the other sta-tion (every 15 or 25 seconds when in range).OFF: No alert beeps sound.Set Mode Item 3 [AR INT]Function: Selects the Polling Interval during ARTS operation.Available Values: 25 SEC/15 SECDefault: 25SECSet Mode Item 4 [ARS]Function: Enables/Disables the Automatic Repeater Shift function.Available Values: ARS. ON/ARS.OFFDefault: ARS. ONSet Mode Item 5 [BCLO]Function: Enables/Disables the Busy Channel Lock-Out feature.Available Values: BCL. ON/BCL.OFFDefault: BCL.OFFSet Mode Item 6 [BEEP]Function: Enables/Disables the beeper.Available Values: KEY+SC/KEY/OFFDefault: KEY+SCKEY+SC: The beeper sounds when you press any key, or when the scanner stops.KEY: The beeper sounds when you press any key.OFF: Beeper is disabled.Set Mode Item 7 [BELL]Function: Selects the number of CTCSS/DCS Bell ringer repetitions.Available Values: OFF/1T/3T/5T/8T/CONT (Continuous ringing)Default: OFFSET (MENU) MODE