York 12 SEER H*RC018 THRU 060 Technical Manual
Contents |
036-21137-004 Rev. C (0505)6 Unitary Products Group- = Not applicable.COOLING CAPACITY - With Air Handler CoilsUNIT MODELAIR HANDLER COIL1MODELCOOLINGMODEL ELECTRIC2HEAT KW W RATEDCFMNET MBH SEERW/O TXVSEERWITH TXV 3 EERTOTAL SENS.1 PH 12 SEER AC WITH N1AH / G2FDH2RC018S06 N1AHB0806 2,5,8,10 17 G2FD024(S,H)17 600 19.6 13.2 12.50 12.50 11.60H2RC024S06 N1AHB0806 2,5,8,10 17 G2FD024(S,H)17 750 23.6 16.9 12.00 12.00 11.00N1AHB0806 2,5,8,10 17 G2FD030(S,H)17 750 24.0 17.3 12.00 12.00 11.10H2RC030S06 N1AHB1206 2,5,8,10 17 G2FD030(S,H)17 1000 30.0 21.3 12.00 12.00 11.00N1AHB1206 2,5,8,10 17 G2FD036(S,H)17 1000 30.6 21.8 12.25 12.25 11.20H2RC036S06 N1AHB1206 5,8,10,15,19 17 G2FD036(S,H)17 1200 33.8 23.6 11.50 11.50 10.70N1AHB1206 5,8,10,15,19 17 G2FD046(S,H)17 1200 35.0 24.4 12.00 12.00 10.90H2RC042S06 N1AHC1606 5,8,10,15,20 21 G2FD042(S,H)21 1400 41.0 29.3 12.00 – 10.50N1AHC1606 5,8,10,15,20 21 G2FD048(S,H)21 1400 42.5 30.6 12.00 – 10.75H2RC048S06N1AHC1606 5,8,10,15,20 21 G2FD048(S,H)21 1575 46.5 36.0 12.20 12.20 10.90N1AHD2006 8,10,15,20,25,30 24 G2FD060(S,H)24 1575 48.0 36.4 12.50 12.50 11.10N1AHD2006 8,10,15,20,25,30 24 G2FD061H24 1575 48.5 34.5 12.50 12.50 11.20H3RC060S06 N1AHD2006 8,10,15,20,25,30 24 G2FD060(S,H)24 1800 57.5 42.6 – 12.00 10.40N1AHD2006 8,10,15,20,25,30 24 G2FD061H24 1850 58.0 43.2 – 12.00 10.453 PH 12 SEER AC WITH N1AH / G2FDH1RC036S(25,46)N1AHB1246 5,8,10,15,18 17 G2FD036(S,H)17 1255 33.6 24.9 – 12.00 10.65N1AHB1246 5,8,10,15,18 17 G2FD046(S,H)17 1250 34.8 25.8 – 12.00 10.95N1AHC1646 5,8,10,15,18 21 G2FD048(S,H)21 1600 45.5 33.7 – 12.20 11.20H1RC048S(25,46) N1AHD2046 8,10,15,20,25,30 24 G2FD060(S,H)24 1620 47.0 34.8 – 12.50 11.45N1AHD2046 8,10,15,20,25,30 24 G2FD061H24 1600 47.5 35.2 – 12.50 11.50H1RC060S(25,46) N1AHD2046 8,10,15,20,25,30 24 G2FD060(S,H)24(T) 1800 56.5 43.4 – 12.00 10.10N1AHD2046 8,10,15,20,25,30 24 G2FD061H24 1800 56.5 43.8 – 12.00 10.151 PH 12 SEER / N1VS - VARIABLE SPEEDH2RC018S06 N1VSB12 10,15,18 17 G2FD024(S,H)17 650 20.2 13.2 13.75 13.75 12.80H2RC024S06 N1VSB12 10,15,18 17 G2FD024(S,H)17 725 24.2 16.9 13.35 13.35 12.15N1VSB12 10,15,18 17 G2FD036(S,H)17 775 25.2 17.8 13.50 13.50 12.50H2RC030S06N1VSB12 10,15,18 17 G2FD036(S,H)17 1000 31.0 21.9 13.25 13.25 12.15N1VSB12 10,15,18 17 G2FD046(S,H)17 1000 32.0 22.3 13.75 13.75 12.55N1VSB12 10,15,18 17 G2FD046(S,H)17 1000 32.0 22.3 13.75 13.75 12.55H2RC036S06N1VSB12 10,15,18 17 G2FD036(S,H)17 1200 34.8 23.6 12.40 12.40 11.35N1VSB12 10,15,18 17 G2FD046(S,H)17 1210 35.8 24.4 13.00 13.00 11.65N1VSC16 10,15,18 21 G2FD048(S,H)21 1155 36.8 25.1 13.40 13.40 12.20H2RC042S06 N1VSC16 10,15,18 21 G2FD048(S,H)21 1400 43.0 30.6 13.00 – 11.55N1VSC16 10,15,18 21 G2FD048(S,H)21 1590 47.0 30.6 12.80 – 11.40H2RC048S06N1VSC16 10,15,18 21 G2FD048(S,H)21 1590 47.0 34.9 12.80 12.80 11.40N1VSD20 10,15,18,30 24 G2FD060(S,H)24 1560 48.5 36.0 13.25 13.25 11.75N1VSD20 10,15,18,30 24 G2FD061H24 1560 49.0 36.4 13.30 13.30 11.90H3RC060S06 N1VSD20 10,15,18,30 24 G2FD060(S,H)24 1780 56.0 42.3 – 12.10 10.25N1VSD20 10,15,18,30 24 G2FD061H24 1780 56.5 42.7 – 12.25 10.401 PH 12 SEER AC / F2RP / RC / FC 4 , 5H2RC018S06 F2RC/F2FC024 5,8,10 18 – 600 20.0 13.2 12.50 12.50 11.70F2RP/F2FP024 5,8,10 18 – 600 20.0 13.2 12.50 12.50 11.70H2RC024S06F2RC/F2FC024 5,8,10 18 – 750 23.4 17.5 11.50 11.50 10.85F2RC/F2FC030 5,8,10,15 18 – 750 23.4 17.5 11.50 11.50 10.85F2RP/F2FP024 5,8,10 18 – 750 23.6 17.5 12.00 12.00 10.90F2RP/F2FP030 5,8,10,15 18 – 750 24.0 17.9 12.00 12.00 11.10H2RC030S06F2RC/F2FC030 5,8,10,15 18 – 1000 29.8 21.5 12.00 12.00 11.00F2RC/F2FC036 5,8,10,15 21 – 1000 31.0 22.4 12.25 12.25 11.30F2RP/F2FP030 5,8,10,15 18 – 1000 30.2 22.9 12.00 12.00 11.15F2RP/F2FP036 5,8,10,15,19 21 – 1000 30.2 23.5 12.00 12.00 11.15H2RC036S06F2RC/F2FC036 5,8,10,15 21 – 1200 34.6 26.2 12.00 12.00 10.85F2RP/F2FP036 5,8,10,15,19 21 – 1200 34.6 26.2 12.00 12.00 10.85F2RP/F2FP042 5,8,10,15 21 – 1200 34.8 26.3 11.60 11.60 10.70F2FP048 5,8,10,15,20,25 24 – 1200 35.4 26.7 12.00 12.00 10.90H2RC042S06 F2RP/F2FP042 5,8,10,15 21 – 1400 40.5 28.9 11.80 – 10.35F2FP048 5,8,10,15,20,25 24 – 1400 42.5 30.5 12.00 – 10.55H2RC048S06F2FP048 5,8,10,15,20,25 24 – 1565 46.5 34.9 11.40 11.40 10.75F2FP060 5,8,10,15,20,25 24 – 1575 48.0 35.9 11.50 11.50 10.70F2FV060 8,10,15,20,25 24 – 1560 48.5 35.9 13.20 13.20 11.70H3RC060S06 F2FP060 5,8,10,15,20,25 24 – 1800 56.0 42.0 – 12.00 10.00F2FV060 8,10,15,20,25 24 – 1780 56.0 42.3 – 12.10 10.30Rated in accordance with DOE test procedures (Federal Register 12-27-79 and 3-18-88) and ARI Standards 210.Cooling MBH based on 80°F entering air temperature, 50% RH, and rated air flow.EER (Energy Efficiency Ratio) is the total cooling output in BTU’s at a 95°F outdoor ambient divided by the total electric power in watt-hours at those conditions.SEER (Seasonal Energy Efficiency Ratio) is the total cooling output in BTU’s during a normal annual usage period for cooling divided by the total electric powerinput in watt-hours during the same period.1. G2FD coils available with a factory installed horizontal drain pan. See price pages for specific model number.2. Single phase units require single phase 2HK heaters. Three phase units require three phase 2HK heaters.3. TXV = Thermal Expansion Valve kit required. Use 1TV700 series kit.4. To meet R=4.2 insulation requirements, substitute F2FP for F2RP, and F2FC for F2RC. models. All ratings remain the same.5. FG8, FG9, and FL8 furnaces and F2RP / F2RC air handlers have B.O.D (Blower on Delay) standard. |
Related manuals for York 12 SEER H*RC018 THRU 060
York H*RC018 THRU 060 Technical Manual
York THRU H*RA018 THRU 060 Technical Manual
York H*RD018 THRU 060 Technical Manual
York 13 SEER - R410A CZB018 THRU 060 Technical Manual
York 018-060 Technical Manual
York E*BA-F018 THRU 060 Technical Manual
York CZF024 THRU 060 Technical Manual
York CZH024 THRU 060 Technical Manual
York H*RD018 Technical Manual
York STELLAR PLUS H4DH018 THRU 060 Technical Manual
manualsdatabase
Your AI-powered manual search engine