P5417054 33• This “Individual Louver Setting” is NOT available when two wired controllers are used in the sameH-LINK. (This includes the combination with the wired controller and the wireless controller.)• The individual louver setting is available for up to 16 indoor units by single wired controller.• The individual louver settings with the same refrigerant cycle are available for up to four indoor unitswithout the communication cable for the wired controller.4. Select the indoor unit to change the louver direction bypressing “ ” and press “OK”.(This screen is NOT displayed when only one indoorunit is connected to the wired controller. In this case,move to Item 5.)5. Press “ ” and select the louver direction.The selected louver is opened and the other louvers areclosed.6. Press “Menu” while “Back/Help” is pressed.The confirmation screen will be displayed.7. Select “Yes” and press “OK”. Screen of Item 5. will bedisplayed after the change of setting is confirmed.If “No” is selected and “OK” is pressed, the screen willreturn to Item 5.▫ Regarding the “Individual Louver Setting”, thelouver selected at Item 5. will be set as “Number1” and the other louver numbers will be changedautomatically as shown at right.OKIndividual Louver Setting01-0101-0201-03Select unit to set.01-04Entr RtrnSel. BackOKIndividual Louver Setting:01-03Adjust air direction & louver angle.1 2 3 4Adj.Sel. Entr RtrnBackChange louver outlet number?(2 1, 3 2, 4 3, 1 4)Louver Outlet Setting:01-03Yes NoSel. Entr RtrnOK Back8.10 Control of Dew Condensation PreventionThis function limits the occurrence of condensation around louvers. Condensation can occur when the airconditioner has run in cooling mode over a prolonged period of time at 80.6 o F DB (27o C DB) and a highrate of humidity (Relative Humidity: Approximately 80%). If there is any anticipation of upcoming operationunder these conditions, set optional function K8 to "01" on the function selection menu to safeguard againstcondensation.3. Select “Individual Louver Setting” from Individual LouverSetting screen and press “OK”.OKCancel INDV Louver SETIndividual Louver SettingIndividual Louver SettingEntr RtrnSel. Back