5219967-UTG-A-0716Johnson Controls Unitary Products 191. Airflow tested with dry coil conditions, without air filters, at 230 volts2. Applications above 0.8" w.c. external static pressure are not recommended.3. Brushless DC high efficiency standard ECM blower motor used for all indoor blower assemblies.4. Minimal variations in airflow performance data results from operating at 208 volts. Data above may be used in those cases.5. Minimal variations in airflow performance data results from using downflow duct applications. Data above may be used in those cases.60100ContinuousFanA 2077 2043 2006 1961 1922 1880 1836 1789 1744 1696B 1879 1843 1807 1763 1723 1679 1635 1590 1536 1493C 1683 1648 1604 1560 1515 1468 1424 1377 1330 1284D 1497 1451 1402 1354 1305 1258 1206 1156 1103 1055High CoolA 2149 2114 2077 2030 1989 1948 1905 1859 1816 1768B 2013 1977 1941 1898 1860 1816 1772 1726 1677 1630C 1936 1900 1864 1822 1783 1739 1695 1649 1597 1551D 1719 1685 1642 1600 1555 1508 1465 1418 1372 1327Low CoolA 1629 1591 1546 1502 1455 1409 1362 1315 1266 1220B 1558 1516 1469 1423 1375 1329 1280 1232 1181 1135C 1453 1406 1355 1305 1255 1207 1153 1100 1047 997D 1410 1361 1307 1255 1204 1155 1100 1044 992 938High HeatA 1739 1705 1664 1620 1577 1530 1487 1441 1393 1348B 1558 1516 1469 1423 1375 1329 1280 1232 1181 1135C 1410 1361 1307 1255 1204 1155 1100 1044 992 938D 1323 1270 1213 1156 1104 1052 993 933 880 821Low HeatA 1594 1553 1507 1462 1415 1369 1321 1274 1223 1178B 1323 1270 1213 1156 1104 1052 993 933 880 821C 1181 1118 1049 980 913 857 795 743 696 640D 1025 950 868 788 713 654 591 505 458 41560125ContinuousFanA 2077 2043 2006 1961 1922 1880 1836 1789 1744 1696B 1879 1843 1807 1763 1723 1679 1635 1590 1536 1493C 1683 1648 1604 1560 1515 1468 1424 1377 1330 1284D 1497 1451 1402 1354 1305 1258 1206 1156 1103 1055High CoolA 2149 2114 2077 2030 1989 1948 1905 1859 1816 1768B 2013 1977 1941 1898 1860 1816 1772 1726 1677 1630C 1936 1900 1864 1822 1783 1739 1695 1649 1597 1551D 1719 1685 1642 1600 1555 1508 1465 1418 1372 1327Low CoolA 1629 1591 1546 1502 1455 1409 1362 1315 1266 1220B 1558 1516 1469 1423 1375 1329 1280 1232 1181 1135C 1453 1406 1355 1305 1255 1207 1153 1100 1047 997D 1410 1361 1307 1255 1204 1155 1100 1044 992 938High HeatA 2259 2221 2183 2142 2099 2060 2015 1975 1931 1882B 2093 2059 2023 1977 1938 1896 1852 1805 1760 1712C 1908 1872 1835 1792 1753 1709 1665 1619 1566 1522D 1760 1726 1685 1641 1598 1552 1510 1463 1413 1370Low HeatA 2259 2221 2183 2142 2099 2060 2015 1975 1931 1882B 1965 1929 1893 1851 1813 1769 1724 1678 1628 1580C 1701 1666 1623 1580 1535 1488 1445 1397 1351 1305D 1683 1648 1604 1560 1515 1468 1424 1377 1330 1284AIRFLOW PERFORMANCE - SIDE DUCT APPLICATION (Continued)Model Jumper PositionExternal Static Pressure (Inches WC)0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0SCFM SCFM SCFM SCFM SCFM SCFM SCFM SCFM SCFM SCFM