5167821-YTG-J-0518Johnson Controls Ducted Systems 23115°F 125°F100077 33.8 3.0 - 20.8 13.1 - - - 28.9 3.4 - 20.4 11.8 - - -72 32.3 3.0 - 23.8 18.0 12.3 - - 28.8 3.4 - 22.7 16.8 10.9 - -67 30.8 3.0 - 26.7 23.0 17.2 11.5 - 28.4 3.4 - 24.9 21.8 15.9 10.0 -62 30.4 3.0 - 29.1 27.9 22.2 16.5 10.8 28.0 3.4 - 27.4 26.8 20.8 14.8 8.9120077 34.5 3.0 - 20.8 11.6 - - - 30.0 3.4 - 20.0 10.2 - - -72 33.2 3.0 - 24.5 18.1 11.6 - - 29.7 3.4 - 23.0 16.6 10.1 - -67 31.9 3.0 31.7 28.1 24.5 18.0 11.5 - 29.3 3.4 - 26.0 23.0 16.5 10.0 -62 31.9 3.0 31.7 31.4 31.0 24.5 17.9 11.3 29.3 3.4 - 29.1 29.1 22.8 16.2 9.657 31.8 3.0 31.6 31.6 31.6 30.9 24.2 17.6 29.3 3.4 - 29.1 29.1 29.1 22.5 15.8140077 35.2 3.0 31.7 20.9 10.0 - - - 31.1 3.3 30.6 19.5 8.5 - - -72 34.0 3.0 32.3 25.2 18.1 11.0 - - 30.6 3.4 30.3 23.3 16.3 9.3 - -67 33.1 3.0 32.9 29.5 26.1 18.9 11.6 - 30.3 3.4 30.1 27.1 24.1 17.0 9.9 -62 33.3 3.0 33.0 33.0 33.0 26.7 19.3 11.8 30.6 3.4 30.2 30.2 30.2 24.8 17.6 10.457 33.6 3.0 33.1 33.1 33.1 33.1 27.0 19.3 30.9 3.4 30.3 30.3 30.3 30.3 25.2 17.9160077 35.9 2.9 33.3 20.9 8.5 - - - 32.1 3.3 31.4 19.1 6.9 - - -72 34.9 3.0 33.7 25.9 18.1 10.3 - - 31.5 3.3 31.2 23.7 16.1 8.5 - -67 34.2 3.0 34.0 30.9 27.7 19.7 11.6 - 31.3 3.4 31.1 28.2 25.3 17.6 9.9 -62 34.8 3.0 34.3 34.3 34.3 29.0 20.7 12.3 32.0 3.3 31.3 31.3 31.3 26.8 18.9 11.157 35.4 2.9 34.5 34.5 34.5 34.5 29.7 21.1 32.6 3.3 31.5 31.5 31.5 31.5 27.9 20.0180072 35.7 2.9 35.0 26.6 18.1 9.7 - - 32.4 3.3 32.2 24.0 15.9 7.7 - -67 35.4 2.9 35.2 32.3 29.3 20.5 11.6 - 32.3 3.3 32.1 29.3 26.5 18.2 9.9 -62 36.3 2.9 35.6 35.6 35.6 31.3 22.1 12.8 33.3 3.3 32.4 32.4 32.4 28.7 20.3 11.957 37.2 2.9 35.9 35.9 35.9 35.9 32.5 22.8 34.2 3.3 32.7 32.7 32.7 32.7 30.7 22.1200072 36.6 2.9 36.4 27.3 18.1 9.0 - - 33.3 3.3 - - - - - -67 36.5 2.9 36.4 33.7 30.9 21.3 11.7 - 33.3 3.3 - - - - - -62 37.8 2.9 36.9 36.9 36.9 33.6 23.5 13.3 34.6 3.3 - - - - - -57 39.0 2.9 37.4 37.4 37.4 37.4 35.2 24.6 35.9 3.3 - - - - - -1. These capacities are gross ratings. For net capacity, deduct air blower motor, MBh = 3.415 x kW. Refer to the appropriate BlowerPerformance Table for the kW of the supply air blower motor.2. These ratings include the condenser fan motors (total 1 kW) and the compressor motors but not the supply air blower motor.ZT049 Low Speed Compressor (4.0 Ton) (Continued)Air onEvaporator CoilTemperature of Air on Condenser CoilTotalCapacity 1(MBh)TotalInput(kW) 2Sensible Capacity (MBh) TotalCapacity 1(MBh)TotalInput(kW) 2Sensible Capacity (MBh)CFM WB(°F)Return Dry Bulb (°F) Return Dry Bulb (°F)90 85 80 75 70 65 90 85 80 75 70 65