5495504-YTG-B-051864 Johnson Controls Unitary ProductsPERFORMANCE DATA - 5 TONMultipliers for determining the performance with other indoor sections.NOTE: For dry bulb temperatures different than those listed (between 73-87 °F), sensible capacity increases by 1060 BTUH per 1000 CFM per degree above the listedtemperature and decreases by 1060 BTUH per 1000 CFM per degree below the listed temperature.CONDENSER-ONLY DATA (OUTDOOR UNIT)MODELSATURATED SUCTION@ COMPRESSOROutdoor Ambient Temperature55 °F 65 °F 75 °F 85 °F 95 °F 105 °F 115 °FT (°F) P (PSIG) MBH KW MBH KW MBH KW MBH KW MBH KW MBH KW MBH KWYCD60B21S35 107 54.3 2.63 51.9 2.96 49.3 3.33 46.6 3.74 43.8 4.20 40.8 4.76 37.6 5.4240 119 59.7 2.67 56.9 3.00 54.0 3.37 51.1 3.77 48.0 4.24 45.0 4.78 41.6 5.4245 130 65.4 2.72 62.3 3.05 59.1 3.42 55.8 3.83 52.7 4.29 49.2 4.83 45.8 5.4450 143 71.3 2.78 67.9 3.12 64.5 3.48 61.0 3.89 57.4 4.35 53.8 4.88 50.2 5.4855 156 77.6 2.86 73.9 3.19 70.2 3.56 66.4 3.96 62.4 4.43 58.6 4.95 54.7 5.56Notes:1. For Outdoor Unit (Condenser) performance only. Data does not include the effects of air handler power or heat.2. Performance based on 15°F subcooling and 15°F superheat at the Outdoor Unit base valves.a. Increase capacity by 1% for each 2°F increase in subcooling.b. Decrease capacity by 1% for each 2°F decrease in subcooling.3. Maximum recommended condensing temperature is 140°F.COOLING PERFORMANCE DATAOUTDOOR UNIT MODEL NO. YCD60B21SINDOOR COIL MODEL NO. CF60CXA1AIR TEMP.ENTERINGOUTDOOR UNIT (°F)ID CFM 1520 1720 1920ID DB (°F) 80 80 75 80 80 80 80 75 80 80 80 80 75 80 80ID WB (°F) 57 62 62 67 72 57 62 62 67 72 57 62 62 67 7255T.C. 50.4 55.0 55.3 57.5 60.4 53.0 55.9 56.3 58.8 59.2 55.5 56.8 57.2 60.1 57.9S.C. 50.4 45.3 40.7 38.7 30.9 52.6 47.0 41.8 39.8 31.0 52.5 48.6 42.9 41.0 31.1KW 3.24 3.30 3.29 3.33 3.35 3.34 3.38 3.38 3.41 3.43 3.45 3.47 3.46 3.50 3.5265T.C. 50.8 54.9 54.9 58.0 60.0 52.6 55.5 55.8 58.9 59.5 54.5 56.1 56.7 59.9 59.0S.C. 50.8 46.3 40.7 38.9 30.5 52.6 48.5 42.1 40.3 31.1 54.0 50.8 43.5 41.6 31.7KW 3.57 3.64 3.62 3.67 3.69 3.67 3.71 3.71 3.75 3.78 3.77 3.78 3.79 3.84 3.8675T.C. 51.1 54.8 54.4 58.4 59.5 52.3 55.1 55.2 59.1 59.8 53.4 55.4 56.1 59.8 60.1S.C. 51.1 47.2 40.7 39.1 30.2 52.3 50.1 42.3 40.7 31.2 53.4 53.1 44.0 42.3 32.2KW 3.90 3.97 3.95 4.01 4.03 3.99 4.03 4.04 4.09 4.12 4.08 4.10 4.12 4.18 4.2085T.C. 49.1 52.4 51.8 57.0 59.7 50.5 53.0 52.5 57.0 59.2 51.9 53.6 53.3 57.0 58.6S.C. 49.1 46.4 39.4 38.9 30.3 50.5 49.3 41.1 40.4 31.1 51.9 52.2 42.8 41.8 31.9KW 4.35 4.41 4.40 4.47 4.51 4.44 4.49 4.48 4.55 4.59 4.54 4.57 4.57 4.63 4.6795T.C. 47.0 49.9 49.2 55.7 60.0 48.7 50.9 49.8 55.0 58.6 50.3 51.9 50.4 54.3 57.2S.C. 47.0 45.5 38.2 38.6 30.5 48.7 48.5 39.9 40.0 31.0 50.3 51.4 41.6 41.4 31.5KW 4.79 4.85 4.84 4.92 4.98 4.90 4.94 4.93 5.00 5.06 5.00 5.03 5.01 5.08 5.15105T.C. 44.1 45.5 45.2 51.6 56.7 45.9 46.5 46.2 51.5 55.8 47.6 47.5 47.1 51.5 54.8S.C. 44.1 43.7 36.2 36.7 29.0 45.9 45.8 38.2 38.6 29.6 47.6 47.5 40.3 40.4 30.3KW 5.38 5.41 5.41 5.47 5.57 5.47 5.49 5.49 5.56 5.67 5.57 5.57 5.57 5.65 5.78115T.C. 41.2 41.1 41.3 47.4 53.5 43.0 42.1 42.5 48.1 53.0 44.9 43.0 43.7 48.7 52.4S.C. 41.2 41.1 34.2 34.9 27.4 43.0 42.1 36.6 37.2 28.3 44.9 43.0 39.0 39.4 29.1KW 5.96 5.97 5.97 6.02 6.17 6.05 6.04 6.05 6.12 6.29 6.15 6.12 6.12 6.22 6.40NOTE: ALL CAPACITIES INCLUDE INDOOR FAN HEAT. KW VALUES ARE FOR THE SYSTEM (OUTDOOR + INDOOR).Green shaded cells are ACCA (TVA) conditions.Blue shaded cells are AHRI conditions.