8 Enclosure8.1 Technical data ZAdyn4C MRL8.1.1 ZAdyn4C 011 - 032 MRLZAdyn4CS011-MRL-AI/BI/BE4CS013-MRL-AI/BI/BE4CS017-MRL-AI/BI/BE4CS023-MRL-AI/BI/BE4CS032-MRL-AI/BI/BEElectrical dataMains connection voltage [V] 3~180 ... 440 absolutMains frequency [Hz] 50 / 60 (±1,5 Hz)Typ. motor output (400 V) [kW] 4.6 5.5 7.5 11 14Duty cycle at rated current and clock frequency8 kHz[%] 60Rated current for 60% duty ratio and clockfrequency 8 kHz fix[A] 11 13 17 23 32Nominal current for 60% switch-on duration andswitching frequency 12 kHz fix1)[A] 9 11 15 20 27Nominal current for 60% switch-on duration andswitching frequency 16 kHz fix1)[A] 8 10 13 17 23Max. operating current (for max. 3 s) [A] 20 24 31 42 58Power loss at rated current, clock frequency8 kHz and duty ratio of 60 %[W] 193 204 242 309 424Power loss at rated current, clock frequency16 kHz and duty ratio of 60%[W] 298 326 373 475 612Heat dissipation standstill 4CS [W] max. 12Heat dissipation stand-by 1 4CS [W] max. 12Heat dissipation stand-by 2 4CS [W] max. 12Switching frequency [kHz] 4 ... 16Brake contactor power loss [W] max. 12Motor frequency [Hz] max. 200Max. terminal cross-section line/motor/brakechopper/brake resistor[mm2] 16Min. cable cross-sectionBrake-Chopper / Brake-Resistor[mm2] 11 11 11 11 14Min. cable cross-sectionMotor[mm2] 11 11 11 11 14Ambient conditionsThe user must ensure that the specified ambient conditions are observed.Protection rating IP20Ambient temperature for operation [°C] 0 ... 45, from 40 °C power reduction by1.66% per 1 k temperatureincreaseRelative humidity [%] 90 / condensation prohibitedInstallation height [m überNN]bis 2000, ab 1000 m Leistungsreduzierung um 1% pro 100 mStorage and shipping temperature [°C]Degree of soiling (in acc. with DIN EN 61800-5-1)2Physical dataWeight ZAdyn4CS MRL AI [kg] 23.9 24.7 25,1 26.2 28.5Weight ZAdyn4CS MRL BI [kg] 23.1 23.9 24.3 25.4 27.7Weight ZAdyn4CS MRL BE [kg] 20.9 21.7 22.1 23.2 25.5Dimensions h x w x d [mm] 429 x 300 x 1911) with a variable switching frequency (power component/M_PWM=AUTO menu), there is no reduction in powerOriginal operating instructionsZAdyn4C MRL EnclosureR-TBA14_01-GB 1845 Part.-No. 00163419-GB37/44