ZKTeco inBIO 480 Installation And Connection Manual
2. InstallationEquipmentinBIO 480 Installation and Connection GuideSelect two of the elliptical holes on Hang the equipment on the upperedge of the rear iron cover, andthen press the equipment down.Push the equipment backward to hangthe entire equipment onto the rear cover.on the surface for fixing (Which maybe on a distribution cabinet, ceilingor other weatherproof position).1 2 31.Cautions1)The access controller provides lock control output. For a lock which should be open when being energized and be closedUnlock at power offUnlock at power on++--Enlar ged diag ramNCNOCOMwhen being de-energized, the “COM” and “ NO” terminals should be used. For a lock which should be open when beingde-energized and be closed when being energized, the “COM” and “ NC” terminals should be used.DiodeDiodeLockLock++-- FR107FR1073. Lock ConnectionExternal power supply for electronic lockpqRS-485 EXT WIEGAND 3 IN5 IN6 OUT5 OUT6 WIEGAND 4 IN7 IN8 OUT7 OUT8 131312121101313121211016WIEGAND 1 IN1 IN2 OUT1 OUT2 WIEGAND 2 IN3 IN4 OUT3 OUT41 3POWER1 5 1 10 1 2 1 2 1 3 1 3 1 10 1 2 1 2 1 3ResetPCTCP/IP EthernetRS485 PortsCard Reader1# Controller 2# Controller n# ControllerpqRS-485 EXT WIEGAND 3 IN5 IN6 OUT5 OUT6 WIEGAND 4 IN7 IN8 OUT7 OUT8 131312121101313121211016WIEGAND 1 IN1 IN2 OUT1 OUT2 WIEGAND 2 IN3 IN4 OUT3 OUT41 3POWER1 5 1 10 1 2 1 2 1 3 1 3 1 10 1 2 1 2 1 3ResetpqRS-485 EXT WIEGAND 3 IN5 IN6 OUT5 OUT6 WIEGAND 4 IN7 IN8 OUT7 OUT8 131312121101313121211016WIEGAND 1 IN1 IN2 OUT1 OUT2 WIEGAND 2 IN3 IN4 OUT3 OUT41 3POWER1 5 1 10 1 2 1 2 1 3 1 3 1 10 1 2 1 2 1 3ResetpqRS-485 EXT WIEGAND 3 IN5 IN6 OUT5 OUT6 WIEGAND 4 IN7 IN8 OUT7 OUT8 131312121101313121211016WIEGAND 1 IN1 IN2 OUT1 OUT2 WIEGAND 2 IN3 IN4 OUT3 OUT41 3POWER1 5 1 10 1 2 1 2 1 3 1 3 1 10 1 2 1 2 1 3Reset1) TCP/IP Mode:2) RS485 Mode:3) The recommended bus length of RS485 communication is less than 600 meters.4.Equipment Communication!485-485+GND485-485-485- 485+485+485+ GNDGNDGNDSerial Bus4 3 2 14 3 2 14 3 2 18# Controller2# Controller1# ControllerpqRS-485 EXT WIEGAND 3 IN5 IN6 OUT5 OUT6 WIEGAND 4 IN7 IN8 OUT7 OUT8 131312121101313121211016WIEGAND 1 IN1 IN2 OUT1 OUT2 WIEGAND 2 IN3 IN4 OUT3 OUT41 3POWER1 5 1 10 1 2 1 2 1 3 1 3 1 10 1 2 1 2 1 3ResetpqRS-485 EXT WIEGAND 3 IN5 IN6 OUT5 OUT6 WIEGAND 4 IN7 IN8 OUT7 OUT8 131312121101313121211016WIEGAND 1 IN1 IN2 OUT1 OUT2 WIEGAND 2 IN3 IN4 OUT3 OUT41 3POWER1 5 1 10 1 2 1 2 1 3 1 3 1 10 1 2 1 2 1 3ResetpqRS-485 EXT WIEGAND 3 IN5 IN6 OUT5 OUT6 WIEGAND 4 IN7 IN8 OUT7 OUT8 131312121101313121211016WIEGAND 1 IN1 IN2 OUT1 OUT2 WIEGAND 2 IN3 IN4 OUT3 OUT41 3POWER1 5 1 10 1 2 1 2 1 3 1 3 1 10 1 2 1 2 1 3ResetNotes:Lock Power++--Lock Power3) Each relay may work under the wet mode or dry mode by setting the jumper terminal. If the 12V power1 2 3 4supply inside the access controller uses external power supply, the output of each relay is under the “wet mode”.OUT4RelayRelayJumper terminalsJumper terminalswet mode:OUT8OUT7RelayRelayOUT3112233dry mode:IN8IN4J24 EnlargementFactory defaultTerminal resistance settingTerminal resistance setting diagram (The first layer of PCB)11 22 33RS485J24Please notice the following cautions. Mis-operation may lead to personal injury or1) Do not energize the system before installation is complete. Never carry out installationVision:1.0.1 Date: July, 20112) All peripheral devices must be grounded.Switch4) When the bus is longer than 300 m, to enhance the stability of communication, it is necessaryactivities when the system is energized.the rear iron cover. Drill two holes2) If the electrical lock is connected to the access control system, you need to parallel one FR107 diode (Equippedin the package) to prevent the self-inductance EMF affect the system, do not reverse the polarities.If the external power supply uses potential free contacts, the “dry mode” should be used. please refer toInstructions for Hardware of C4-200/400 Access Controller.* It is recommended to short 2-3 ports, the output use the “dry mode”, the electronic lock use the external power supply.of lock portsThe PC software communicate with the system through two protocols (RS485 and TCP/IP)for data exchange and remote management. The communication cable should be awayfrom high-voltage lines as far as possible. Do not keep the communication cable in parallelwith power cords or bind them together.RS 485 Convertor1) Internationally accepted RVSP (shielded twisted-pair) wires should be used for communicationto RS485 communication wires should be connected by meanseffectively avoid interference.of bus cascade connection.2) Theoretically, in RS485 communication, one bus may be connected with 64 access controllers.to change J24 on the first layer of PCB (see the figure below) inthe first and the last units (seeunit 8# as shown in the figure above) to short pins 2-3. This method is equivalent to connectequipment failure:Relay output ports and jumper terminals setting (The second layer of PCB)4 3 2 1 1 2 3 41 2 3 4 1 2 3 41 2 3 41 2 3 4PCIt is recommended to conenct with no more than 16 devices.with a resistance of 120 ohm.Jumping TerminalsDistributiondiagram of thefactory defaultjumper cap:1 2 3 43) It is recommended that all wires run through casing pipes which may by PVC or galvanized5) It is recommended that card readers and buttons should be installed at height of 1.4m-1.5m6) It is recommended to use the power supply in case for control panel, and external power4) It is strongly recommended that the length of exposed part of any connection cableshould not be longer than 4 mm. avoidProfessional clamping tools may be used tounintentional contact of exposed wires to avoid short-circuit or communication failure.supply for each lock.ones.above ground. |
Related manuals for ZKTeco inBIO 480
ZKTeco InBio160 Installation And Connection Manual
ZKTeco C5S120 Installation And Connection Manual
ZKTeco ProBio Installation Manual
ZKTeco F6 Installation Manual
ZKTeco F17 Installation Manual
ZKTeco F18 Installation Manual
ZKTeco F18 Installation Manual
ZKTeco F17 Installation Manual
ZKTeco F19 Installation Manual
ZKTeco F19 Installation Manual
This manual is suitable for:
manualsdatabase
Your AI-powered manual search engine