22• For appliances installed in the Republic of Irelandplease refer to NSAI-Domestic Gas InstallationIS813 Current Edition Section7 Permitted Locationsof appliance Table4— Locations and PermanentVentilation requirements-flueless appliances. Note:- L.P.G. cookers MUST NOT be installed belowground level i.e. in a basement or aboard any boat,yacht or other vessel.Levelling the appliance• Adjustment to suit floor conditions or height isobtained by rotating clockwise or anti clockwise thefeet at the front and rear of the appliance. A spiritlevel should be placed on one of the shelves toconfirm the appliance is correctly levelled.Connecting to gas supply• This appliance is designed to be installed with anappliance flexible connection only.• Supply piping should not be less than R3/8.Connection is made to the Rc ½ (½" B.S.P)female threaded entry pipe located just belowthe hob level on the rear right hand side of theappliance.Only liquid sealants to be used when inlet gas pipe isfitted i.e.: do not use P.T.F.E. sealant tape.• Carry out a gas tightness test after connecting tothe gas supply.• The gas bayonet connector must be fitted in theenlarged area indicated.• Take into account that it must be possible to pullthe appliance forward sufficiently. Ensure the hosedoes not become trapped when pushing theappliance into position.Flexible tubing used must comply with BS. 669current edition.LPG Flexible connections must be a type suitablefor L.P.G and capable of operation up to 50 mbarand carry a red stripe, band or label.Fixing the stability chainTo further prevent tilting and for safe usage of theappliance a stability chain should be used. Unscrewthe screw shown in the figure. Then, align the firstloop of the chain with the hole and assemble with thescrew so that the chain stands in its place safely.Check the assembly by gently pulling the chain fromits loose end. Fix the loose end to the rear wall asappropriate for your kitchen. The chain is not suppliedwithin the package of the appliance, but can easily besupplied from the market.IMPORTANT!min 150min 7min 1750max 400 Gas Inlet