10If after the above checks, there is still a fault, call your local Service Force Centre.In-guarantee customers should ensure that the above checks have been made as the engineer will make acharge if the fault is not a mechanical or electrical breakdown.Please note that proof of purchase is required for any in-guarantee service calls.Symptom SolutionNo power to the applianceThe temperature in the freezer is too highThe freezer door will not openThe compressor runs continuouslyThe freezer flaps have frost and ice on.Noise- Check there is power at the socket.- Check there is not a power cut by checking thehousehold lights.- Check the fuse has not blown.- Check the thermostat control knob is turned to thecorrect setting relative to ambient conditions.- Check the ambient temperature is within the appliancesoperating limits of 10°C to 32°C.- Relocate the appliance if necessary.- Has the door just been opened?- If so leave for a few minutes to allow the air pressure toequalise.- Adjust the thermostat control knob to give correcttemperature control. See page 5.- Check that the door is closed.- Large quantities of food have recently been placed inthe cabinet and/or door is frequently opened.- Check that air ventilation is not obstructed.- Ensure the door is not left opened.- Check that nothing is preventing the door from closing.- Is the door gasket intact and clean?Refer to normal operating sounds.SOMETHING NOT WORKING?Before contacting your local Service Force Centre check the following points.IMPORTANT: If you call out an engineer to a fault listed below, or to repair a fault caused by incorrect use orinstallation, a charge will be made even if the appliance is under guarantee.