1 23451 Green and Yellow2 3 amp fuse3 Brown4 Cord clamp5 BlueShould the plug need to be replaced for anyreason, the wires in the mains lead are colouredin accordance with the following code:Green and yellow - EarthBlue - NeutralBrown - Live1. Connect the green and yellow (earth) wireto the terminal in the plug which is markedwith the letter 'E' or the earth symbol ,or coloured green and yellow.2. Connect the blue (neutral) wire to the ter-minal in the plug which is marked with theletter 'N' or coloured black.3. Connect the brown (live) wire to the termi-nal in the plug which is marked with the let-ter 'L' or coloured red.There must be no cut or stray strands of wirepresent. The cord clamp must be secured onthe outer sheath.Warning! Make sure that the cut off plugis disposed of safely. A cut off plug putinto a 13 amp socket is a safety hazard. Thereis a risk of electrical shock.Important! The replacement of the electricalcable must be done by a qualified electrician orcompetent person, according to the currentregulations.Replacement of the connection cableTo replace the connection cable use onlyH05V2V2-F T90 or equivalent type. Make surethat the cable section is applicable to the volt-age and the working temperature. The yellow/green earth wire must be approximately 2 cmlonger than the brown (or black) phase wire.Building Inmin. 55 mmmin. 650 mm560 mmmin. 100 mm30 mm480 mm10 mm11 mm11 mmA3 mmBAA) supplied sealB) supplied bracketsPossibilities for insertionKitchen unit with doorThe panel installed below the hob must be easyto remove and let an easy access in case atechnical assistance intervention is necessary.7www.zanussi.com