14Technical DataDimensions of recessHeight undertop: 593 mm; in coloumn 580 mmWidth 560 ÷ 570 mmDepth 550 mmDimensions of the oven cavityHeight 335 mmWidth 405 mmDepth 400 mmOven capacity 53 litresThis oven must be installed by qualifiedpersonnel.The oven must be installed according to theinstructions supplied.InstallationHeating elements ratingTop element 800 WBottom element 1000 WConvection element 2000 WGrill element 1650 WDouble Grill element 2450 WConvection Fan 25 WOven Light 25 WCooling Fan 25 WTurnspit Motor 25 WTotal Rating 2500 WSupply voltage (50 Hz) 230 VBefore the appliance is connected:1) check that the main fuse and the domestic installationcan support the load;2) check that the power supply is properly earthed incompliance with the current rules;3) check the double pole switch used for the electricalconnection can be easily reached with the appliancebuilt in the forniture unit.The appliance is supplied with connection cable. Aproper plug, according to the electric load specified onthe rating plate, must be fitted to the cable.In case of a direct connection to the mains, it isnecessary that you install a double pole switch betweenthe appliance and the electricity supply, with a minimumgap of 3 mm. between the switch contacts and of a typesuitable for the required load in compliance with thecurrent rules. The yellow-green earth wire must not beinterrupted in any point and should be about 2 cm longerthan the neutral and phase wires.The connection cable has to be placed in order that, ineach part, it cannot reach a temperature 50 °C higherthan the room temperature.After the connection is carried out, test the heatingelements for about 3 minutes.Should the supply cord need to be replaced, use onlythe following cable types: H07 RN-F, H05 RN-F, H05RR-F, H05 VV-F, H05 V2V2-F (T90), H05 BB-F. Theyellow-green earth wire should be about 2 cm longerthan the neutral and phase wires.Electrical connectionTerminal blockThe oven has an easily accessible terminal block, whichis meant to work with an electric single-phase rate of 230V (Fig. 11).The manufacturer disclaims anyresponsability should all the safety measuresnot be carried out.Fig. 11