BUILDING IN1657321548min. 55020600min. 560558589114594595 +/-135SECURING THE APPLIANCE TO THECABINETA BELECTRICAL INSTALLATIONThe manufacturer is not responsible ifyou do not follow the safetyprecautions from the Safety chapters.This appliance is supplied without a main plug anda main cable.CABLECable types applicable for installation orreplacement:H07 RN-F, H05 RN-F, H05 RRF, H05 VV-F, H05V2V2-F (T90), H05 BB-FFor the section of the cable refer to the total poweron the rating plate.CONNECTING THE TERMINAL BOARDThe appliance has a six-pole terminal board. Thejumpers (bridges) are set for operation on a 400 Vthree-phase with a neutral wire.1 = 45 mm2 = 45 mm3 = 60 mm4 = 60 mm= 70 mm1 2 34L 1 – 2 – 3 = phase cablesN 4 = neutral cable= earth cableIf the mains voltage is different, rearrange thejumpers on the terminal board (refer to theconnection diagram below). Connect the groundcable to the terminal. After you connect the supplycable to the terminal board, attach it with a junctionclamp.3N ~ 2N ~ 230V ~230V ~230V ~230V ~1 2 35 41 2 35 41 2 35 4ENERGY EFFICIENCYPRODUCT FICHE AND INFORMATION ACCORDING TO EU 65-66/2014Supplier's name ZanussiModel identification ZOU35902XUEnergy Efficiency Index 100.022