Page 2 Zip Tudor - Installation & Operating Instructions - 81333 - February 2010 V2## Read These Warnings FirstPlease read all installation requirements, installation procedures and precautions beforeinstalling any Zip Tudor water heater.Never attempt to install any Zip Tudor water heater without reading all of the applicableinstructions.Zip Tudor water heater is recommended for sinks and tubs, not recommended for basins.Zip Tudor water heaters are open outlet (vented) water heaters and must not be installedin the same way as mains pressure type water heaters.The outlet from any Zip Tudor water heater must be connected directly to an outlet spouton the sink and must not be obstructed by a tap or valve or in any other way.The water flow is controlled by a cold water tap connected before the water heater. Coldwater pushes hot water out of the tank when the cold water tap is turned ON. Any suchcold water tap should be labelled HOT.This water heater must not be connected to more than one outlet.All plumbing connections must be made in accordance with AS3500.The heater is intended only for indoor use and should never be installed outdoors or beexposed to the elements of nature.Over-sink and under-sink models are NOT interchangeable.The heater is unsuited for use by children or infirm people or those without experience;unless they have been given supervision or instruction by a person responsible for theirsafety. Children should be supervised to ensure they do not play with the heater.If the power supply cord is damaged it must be replaced by a Zip Service Provider or aqualified electrician.Do not remove the cover of the heater under any circumstances without first isolating theheater from the power supply.Outlet temperature should never be set to less than 60°C without due regard to regulationsgoverning the storage temperature of hot water.This unit must not be cleaned by a water jetBefore installing, ensure that the following are available:a) sufficient space to position the heater so there is 270 mm clear access under the heater(over-sink models) or 270mm above (under-sink).b) standard 10 amp 240 volt power outlet within 1500 mm of the heaterc) cold water supply with a minimum working pressure of 50 kPa and a maximum workingpressure of 350 kPa.d) Isolating valve (not supplied)If the pressure may exceed 350 kPa, a 350kPa pressure limiting valve (not supplied) mustbe installed in the cold water supply line.A double check valve (not supplied) is required to comply with the backflow requirementsof AS/NZS3500.1Under-sink models must be installed beneath approved vented mixer taps requiring asingle mounting point on a sink, or tub. (Not recommended for basins)Water pressure under 100 kPa may be sufficient for over-sink heaters but may not operateunder-sink mixer taps satisfactorily.Installation Requirements