Zip Tudor - Installation & Operating Instructions - 81333 - February 2010 V2 Page 3Step One - TapwareNote: Instructions for correct assembly and installation of Tudor tapware is included inthe tapware box. Pay close attention to these instructions.Over-sink models must be installed with an inlet valve to control the flow from the watersupply to the heater. No valve is supplied with the heater. The water supply and valve shouldbe connected after fastening the heater to the wall.Over-sink models are supplied with a 300 mm swivel spout. A 300 mm to 600 mmtelescopic swivel spout (99032) is available as an optional extra.Under-sink models must be installed with approved vented tapware. It is advisable to fit thetap to the sink before mounting the heater to the wall beneath the sink.1. Install the Restrictaflow valve provided, with the isolating valve (not supplied), into themain cold water supply line. The Restrictaflow is adjustable and must be set to deliver nomore than 6Ltr/min (Max.) NOTE: Do not fit the Restrictaflow valve to the tank (See P.5 diag)2. Flush water supply pipes thoroughly to remove any silt or fines.3. Fasten the tap body to the sink using the bolt & plate system provided.4. The hose with a WHITE band on it connects to the tap hole with NO marking.5. The hose with a RED band on it connects to the tap hole with a RED marking.6. The hose with a BLUE band on it connects to the tap hole with a BLUE marking.7. Ensure that the flexible tubes are firmly attached to the base of the tap body and in thecorrect sequence. Refer tapware installation sheet.Do not dismantle the assembled tap body during installation. Mixer taps are factory testedand sealed to provide optimum performance.To adjust water temperature delivered by Solo and Hero mixer taps, see instructions on page7. Such adjustments should be made only by a qualified technician.Step Two - PositioningOver-sink heaters should be installed so that the outlet spout drains to a sink or tub, andwith a clearance of 270 mm beneath the heater to allow for service access.Under-sink heaters should be installed a closely as possible to directly below the outlet tapwith a clearance of 270 mm above the heater.This unit must not be positioned in an area that may be cleaned by a water jet.Step Three - FasteningIt is not necessary to remove the case of the heater during installation.The heater must be wall mounted with two fixing screws as shown in the diagram on page5. Fixing screws must have the strength to support the filled heater.The fixing screws are to protrude 4 mm from the wall as shown in the diagram on page 5 soas to fit into keyhole slots provided on the rear of the heater.NOTE: Failure to correctly fit the Restrictaflow valve (provided) will void the warrantyInstallation Procedure