Is fill lightgreen or red?YES NOYESYESNONONOYESYESPull sensor out of water.Possible Issues:1. Manual lever on valve needsto be turned off.2. Valve is dirty: take valveapart and clean inside.3. Diaphram is torn.4. LED light needs to be alignedwith lens cover.Possible Issues:1. Needs greased-filledwire nut at valve.2. Needs proper wire betweencontroller and valve: solid-core 18-gauge wire withpoly-pro jacket.3. Valve is bad.Possible Issues:1. Needs greased-filled wire nut at valve.2. Needs proper wire between controller and valve:solid-core 18-gauge wire with poly-pro jacket.3. Valve is bad.PCB boardis bad. Sensor is bad.Doesgreen fill lightturn off?Doesgreen fill lightturn off?Is filllight on?Disconnect blue valvewires from control box.Does greenfill light turn off?Wait 20 seconds.Disconnect orange sensorwires from control boxand touch them together.Does sensorlight turn off?Place sensorback in water.Fill Will Not Turn OFFLockout sequencehas taken effect.Call technical support at(707) 776-8200 ext. 260.GREENREDNO5.4 Fill Will Not Turn OFFThis is a troubleshooting flow chart for the K-1100, LX2, and LEV110CK/2G. Use it when the Fill function will notturn off.Page 20ENGLISHJandy Pro Series Levolor ® Electronic Water LevelerModels K-1100, LX2, K-2300, and LEV110CK/2G | Installation and Operation Manual