3400 Series Electric Cylindrical LockElectrical Specifications & Supplemental InstructionsI-LS02201REV 2, 4/18/2018 27390102 Page 1 of 3FUNCTION DESCRIPTION3480EL - Fail Safe Control [GREEN]Outside trim is locked when power is applied and unlocked when power is removed (storeroom function when energized). Locksetwill unlock in the event of a power failure.3480EU - Fail Secure Control [YELLOW]Outside trim is unlocked when power is applied and locked when power is removed. Lockset will lock in the event of a powerfailure. This is the default lock setup.Key FunctionWhen key cylinders are installed into locks, the latch bolt may be momentarily retracted from the outside with key even if lockset iselectrically locked.Request to ExitRequest to Exit (RX) is a SPDT switch that is mounted inside the interior trim of the lockset. The RX switch monitors the activationof the inside trim.ELECTRICAL SPECIFICATIONS3480EL and 3480EU 3480RX Quick Connect Pin AssignmentsMotorized Locking and Unlocking provides 12V/24VFail-Safe/Fail-Secure operation with low powerconsumption.Voltage: 12-24V AC/DC (11V – 30V)Current: 250 mA MAX Inrush, 10 mA MAX HoldingNon-polarized leadsFail-Secure (EL) by DefaultNote: Warranty is void if electronics module isremoved.SPDT mechanical switch. Mainly usedas a dry contact monitoring switch.Voltage Current125 VAC 3 AMP30 VDC 2 AMPRX Wiring DiagramYellow Wire: (common)Red Wire: (normally open)Gray Wire: (normally closed)EU/EL or RX only- If the lock only has EU/EL or RXelectric function the function willbe wired directly into an 8 pinconnector as shown in the imagebelow. The 8 pin connector canbe plugged directly into a HagerQuick Connect Harness Cableduring installation of the lock.- Insert excess wire into theraceway prior to installing thelock body.- See wire color reference chartson page 2 to complete wiring offull door assembly.2-Conductor Wire RunDistance12V/24VWireGauge125’/250’ 22200’/400’ 20300’/600’ 18500’/1000’ 16750’/1500’ 141250’/2500’ 12ELECTRONICS MODULESWITCH ACCESS