OPERATIONS AND SERVICE MANUAL PN 28-0255/1119CONTINUED ON NEXT PAGE3.7 CLEANINg AND SANITIZINg BEvERAgE COMpONENTS - BAg-IN-BOX SYSTEMS - CONTINUEDD. Activate the valve and draw sanitizing solution through the line for a minimum of sixty seconds.This will ensure the line is flushed and filled with sanitizing solution. Allow the line to stand forat least thirty minutes.E. Remove the bag valve from the quick disconnect coupling and reconnect the syrup inlet line tosyrup package. Ready the unit for operation.F. Draw drinks to refill the lines and to flush the sanitizing solution from the dispenser.G. Test the dispenser for proper operation. Taste the dispensed product to ensure there is nooff-taste. If off-taste is found, flush the syrup system again.H. Repeat cleaning, rinsing, and sanitizing procedures for each valve and circuit.3.8 ICE CHUTE CLEANINgIt is recommended to perform this procedure monthly, or more often if desired. Use the cleaningsolution described above. An alternate solution of one part water to one part vinegar may be usedto remove water spots and calcium deposits.A. Turn off power to the dispenser.B. Remove merchandiser.C. Unhook the spring from the upper ice chute by pulling up and out.D. Remove the lower chute by carefully spreading apart the arms of the lower chute.E. Mix the cleaning solution. Put a portion of the solution into a spray bottle. Soak the lower chutein the remaining solution.F. Spray the upper chute with the cleaning solution.G. With a soft sponge, clean the inside of the upper and lower chutes.H. Rinse the lower chute thoroughly.I. Dry the lower chute thoroughly.J. Empty the cleaning solution from the spray bottle, then refill with plain water. Rinse the upperchute thoroughly.K. Dry the upper chute.L. Reinstall the lower ice chute onto the upper chute, then reinstall the spring.M. Reinstall merchandiser.N. Reconnect power to the dispenser.3.9 REMOvAL OF MONITOR FOR SERvICEA. Turn power off to dispenserB. Remove merchandiserC. Loosen the four (4) wing nuts on the side of monitor bracketD. Lift monitor/bracket by grasping the side of the monitor and lifting upi CAUTION/pRECAUCIóN/ATTENTION/ iFOLLOWING SANITIZATION, RINSE WITH END-USE PRODUCT UNTIL THERE IS NO AFTERTASTE. DO NOT USE A FRESHWATER RINSE. THIS IS A NSF REqUIREMENT. RESIDUAL SANITIZING SOLUTION LEFT IN THE SYSTEM CREATESA HEALTH HAZARD. i DESPUéS DE LA ESTERILIZACIóN, ENJUAGUE CON EL PRODUCTO FINAL HASTA qUE ELIMINAREL SABOR qUE qUEDA. NO ENJUAGUE CON AGUA FRESCA. éSTA ES UNA EXIGENCIA DE NSF. SI qUEDA SOLUCIóNDE ESTERILIZACIóN EN EL SISTEMA, GENERA UN PELIGRO PARA LA SALUD. iDéFENSE DE RINCER L’OUTIL à L’EAUFRAICHE IMMéDIATEMENT APRèS UN TRAITEMENT SEPTIqUE.EN CAS DE APRèS-GOûT, NE PURGER AVEC LEPRODUIT FINAL UNE EXIGENCE NSF.
PreviousNext |