E. Once the tank is full, turn the power back on and purge the system bydispensing a carbonated drink. You should only get plain water as the CO2 isstill off. Dispense several times.F. Turn on the CO2 supplyG. Turn off the power in order to reconnect the pump harness. Turn power back on.H. Dispense soda at valve until the carbonator pump comes on. Release thebutton, allow the carbonator to fill and stop (usually a few seconds). Repeat thisprocess until the water is carbonated (about five cycles).I. Place dispenser back into service.NOTE: To check for CO2 leaks, close the valve on the CO2 cylinder and observe ifthe pressure to the system drops with the cylinder valve closed for five minutes.Open the cylinder valve after check.3.4 PURGING THE WATER AND SYRUP SYSTEMSA. Open a dispensing valve until water and syrup are flowing steadily from thevalve. Repeat for each valve.B. Check all of the dispenser's syrup and water connections for leaks and repair ifnecessary.C. Replace the dispenser's splash plate and cup rest.3.5 ADJUSTING WATER FLOW AND WATER TO SYRUP RATIO (BRIX)The water flow can be adjusted between 3.25 oz/sec (96 ml/sec) and 4.50 oz/sec(133 ml/sec) on all dispensing valves. Ensure ice is on the cold plate for at least onehour before you brix the valves. The drink temperature should be no higher than 40degrees F (4.4 degrees C) when the brix is set.A. Remove merchandiser assembly.B. If necessary, rotate switches panel forward and down by releasing the two pinlatches on its sides.C. Rotate light panel, forward and up by releasing the two pin latches on its sidestowards the top.D. Remove nozzle by twisting counterclockwise and pulling down.E. Install Lancer syrup separator (PN 82-3458) in place of nozzle.F. Activate dispensing valve to fill separator syrup tube.G. Hold a Lancer brix cup under the syrup separator and dispense water and syrupinto cup for four seconds. Divide number of ounces of water in cup by four todetermine water flow rate per second.H. To obtain the proper flow, remove protective cap, and use a screwdriver toadjust water flow control.I. Repeat process for each water valve. There can be up to six gray water valveson this dispenser (up to four carbonated water valves and two plain water25 P.N. 28-0580/02