May be subject to change Page 22 of 33Hot waterThe ”Hot water” menu shows the data for production of hot water.” ” indicates that the menu point flashes and can be set to another value.Use of the CTS602 panel:- press ESC to go one step back in the menu- press qpto move up or down in a menu or to adjust anactivated menu- press ENTER to activate a menu- press ENTER to confirm a menu- press OFF to turn off the unit- press ON to turn the unit onHOTWATER EL SUPT11 30°CEL SUPT11 ”30°C”COMPT12 ”55°C”ENTER ENTERFor security reasonsthe compressor stopswhen the watertemperature reachesthe chosentemperature in order toavoid overheating.T12 can be setbetween 5 °C and 80°C.ENTERENTERCOMPT12 55°CENTERThe hotwater isprimarily heated by theheat pump whichdelivers the energy tothe condensator in thewater. If you have avery large demand forhot water the electricalheating element can beengaged in order toreduce time for heatingthe water.T12 can be set between5 °C and 60 °C. it isrecommended to setT12 between 45 °C and55 °CCOMP MAXT12 65°CENTER COMP MAXT12 ”65°C”The electrical heating supplementtemperature T11 is set between 5 °C to10 °C lower than the primary heatingtemperature delivered by thecompressor. It is possible to set the t11temperature between 5 °C and 85 °C.Recommended value: 35-40 °CENTERFigure 16: The ”Hot water" menu