Extract airInstall exhaust air valves in rooms that generate humidity. Place them strategically where they canextract humidity most effectively.Rooms that generate humidity:• Bathroom• Lavatory• Kitchen• Utility roomSupply airInstall supply air valves in living areas. Place them strategically so they cause minimum discomfort. Itis, for instance, not recommended that you install supply air valves in areas where people are inactive,as the supply air may be experienced as draughty.Living areas:• Sitting room• Living room• Bedroom• Home-officeRoof stacksThe position and design of air intake and air discharge should limit pressure oscillations in theventilation unit caused by wind. Their position should also prevent birds and other animals from gettingin. Finally, the position and design should ensure that air intake and the connected duct system arekept free of plants and foreign objects.You must place the air intake so that the risk of a short-circuit from the discharge air is minimized, withattention to the prevailing wind direction.The air intake should be placed at least 0.5 m from the roof surface. On black, flat roofs the distancefrom the roof to the underside of the intake should be at least 1 m to ensure that warm air is not drawninto the building in the summer. Air intakes should be located on the northern or eastern sides ofpitched roofs.You should also install a silencer between the unit and the roof stacks to prevent noise from disturbingyour surroundings.Compact P / Compact P Polar - GEO (English) BY NILAN55