8Hold TimeActiveFromZero TorqueTorque displayTorque inputAuto ResetTriggerPeak Reading with Auto ResetWhen Torque is applied, the NorTronic® will track the torque input until it has exceeded the Active Fromsetting (See page 19) and then enters into peak mode for both Torque & Angle.The angle display is shown as “0°” until the torque is above the Active From setting for the tool. If the SnugTorque is set, the angle display is shown as “0°” until the torque reaches the Snug Torque value (see page13) and then displays the angle value in peak mode.When a peak torque or angle has been applied after which the torque has dropped below the Active Fromsetting, both the torque & angle readings continuously flash for the duration of the Hold Time (see page 21).The displays are then reset to the current torque input.If the Save button (which now becomes latching) has been pressed prior to the Peak beingdetected, the Torque & Angle readings are saved to the Data Store on the NorTronic®.If a Target is in use, press the UP button to delete the last reading that has been saved viathe Delete Last Result? confirmation screen.DeleteLast Result ?Y / NTool TargetHaving already set a Tool Target (see page 13 for more details), the NorTronic® beeps as the applied torqueapproaches the Torque Target (starting slow and getting faster) until a continuous tone is heard when theTarget has been reached. This stops after the Torque has been released.The Torque & Angle digits will be shown as:White = below Active From setting or no Target setYellow = above Active From setting, but below Target Lower LimitGreen = above Target Lower Limit and below Target Upper LimitRed = above Target Upper LimitThe tool Vibrates when the Torque Target or Angle Target has been reached (if enabled in SETUP –Vibrate, see page 20 for more information).TIP: If an angle only target has been set, the beeper sounds as the user approaches the angletarget, quickening in frequency until a continuous tone when the angle target has beenreached.