Electric Lock (12V 6W) Operation SelectionS5 ONFirst input modeMono-stableS5 OFF (DEFAULT)First input modeBi-stableFirst Input Mode SelectionSWINGY can be connected to a closing device such as an electronic key, key selector, transponder, etc.Using the dip switch S5, the signal can be controlled in bistable or monostable mode with an activation time of about 500msec.t01StopNormalClosing devicereadingsAutomatismOperationt01StopNormalClosing devicereadingsAutomatismOperationAntipanic mode SelectionS6 ONAntipanic mode active.In the event of power failure, theequipment moves the doors to the“Stop open” position, and stays inthis condition until power returns ora new logic is selected using themulti-logic selector.S6 OFF (DEFAULT)Antipanic mode disabled.In the event of power failure theequipment continues workingpowered by the battery.Logic right / left opening senseS8 ONWing Left Opening rigid pull armWing Right Opening articulatedpush armS8 OFF (DEFAULT)Wing Right Opening rigid pull armWing Left Opening articulatedpush armWing Left Opening rigidpull arm Wing Right Openingarticulated push armWing Right Openingrigid pull armWing Left Openingarti culated push armQKSW8012S7 ONElectric Lock active.The electrick lock is excited for a few momentsfew millimetres before opening to allow the releaseAs per default setting, the impulse timing of theelectric lock is 120ms.S7 OFF (DEFAULT)Electrick LockdisabledElectric lock must be 12V 6W max.whilst the door is opening, the door reverses athe electric lock. Whilst the door is closing, it acce-lerates and then undergoes a thrust during the lastfew millimetres to rearm the lock.