Samsung AM036NXMDCR manuals
AM036NXMDCR
Table of contents
- Table Of Contents
- Table Of Contents
- Product Specifications
- Disassembly and Reassembly
- Refrigerant pipe installation
- Examples of the incorrect refrigerant pipe installation for Heat Recovery
- Troubleshooting
- Error Code
- How to take measures for each symptom
- outdoor units after completing tracking (Error Code : E202)
- Communication error (1 minute) between Main and Sub Micoms of an Outdoor unit or among Outdoor Units (Error Code : E203)
- MCU branch part setup error inconsecutive connection with the use of 2 branch parts
- MCU branch part setup error Repeated setup for the same address over 3 times
- MCU branch part setup error non-installed address setup
- MCU branch part setup error Overlapping Indoor unit Address setup
- MCU branch part setup error Set as being used without connection to an Indoor unit
- MCU branch part setup error Connect an Indoor unit to a branch part not being used
- MCU branch part setup error Connect more Indoor units than what is actually set up in MCU
- MCU/MCU subcooler entrance/exit sensor error (Open/Short)
- High pressure temperature sensor error (Open/Short) (Error Code : E291 Low pressure temperature sensor error (Open/Short) (Error Code : E296)
- Compressor down by antifreeze control (Error Code: E403)
- Comp. down due to a protective control of high pressure (Error Code : E407)
- Comp. down due to a protective control of low pressure (Error Code : E410)
- Comp. down due to a discharge temperature sensor of a compressor (Error Code : E416)
- Reverse phase detection error (3Phase outdoor unit) (Error Code : E425)
- ESC EEV open error (Error Code : E438)
- Refrigerant leakage error (Error Code : E439)
- Comp down due to OLP temperature control (Error Code : E463)
- Compressor starting/rotation error (Error Code : E461, E467)
- Current error / PFC overload error (Error Code : E462, E484)
- IPM over current error (Error Code : E464)
- DC-Link voltage under/over error (Error Code : E466)
- Others
- PCB Diagram
- Wiring Diagram
- Reference Sheet
- AM036/048/053NXMDCR (Cooling mode)
- AM036/048/053NXMDCR (Main cooling mode)
- AM036/048/053NXMDCR (Heating mode)
- AM036/048/053NXMDCR (Main heating mode)
- Nomenclatures
- Check Operation & Amount of Refrigerant Automatically Checking
- How to troubleshoot of the "Undetermined
- Automatic Commissioning Error Code
- Automatic refrigerant amount detection function (Checking th amount of refrigerant)
manualsdatabase
Your AI-powered manual search engine