ABB RELION RER670 manuals
RELION RER670
Table of contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Section 1 Introduction
- Product documentation
- Document revision history
- Related documents
- Document symbols and conventions
- Section 2 Safety information
- Caution signs
- Note signs
- Section 3 Environmental aspects
- Section 4 Unpacking, inspecting and storing
- Returning an IED damaged in transit
- Section 5 Mounting
- Flush mounting
- Mounting procedure for flush mounting
- panel rack mounting
- Mounting procedure for 19" panel rack mounting
- Wall mounting
- Mounting procedure for wall mounting
- Side-by-side 19" rack mounting
- Mounting procedure for side-by-side rack mounting
- Side-by-side flush mounting
- Mounting procedure for side-by-side flush mounting
- Mounting the coupling capacitor unit REX061 and shunt resistor unit REX062 (REG670 only)
- Shunt resistor unit REX062
- Making the electrical connection
- Front side connectors
- Rear side connectors
- Connection examples for high impedance differential protection
- Connecting to protective earth
- Connecting the power supply module
- Connecting the binary input and output signals
- Making the shield connection
- Making the electrical connection to the rotor and stator injection equipment (REG670 only)
- Coupling capacitor unit REX061
- Connecting injection unit REX060, coupling capacitor unit REX061 and shunt resistor unit REX062
- Connecting and setting voltage inputs
- Making of Ethernet connections
- Connecting remote communication interfaces LDCM
- Installing the serial communication cable for RS485
- Installing the serial communication cable for RS485 SPA/IEC
- Data on RS485 serial communication module cable
- Electrical installation
- Section 7 Checking installation
- Section 8 Removing, repairing and exchanging
- Sending the IED for repair
- Section 9 Technical data
- Case with rear cover
- Flush mounting dimensions
- Side-by-side flush mounting dimensions
- Wall mounting dimensions
- Section 10 Glossary
RELION RER670
Table of contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Section 1 Introduction
- Product documentation
- Document revision history
- Document symbols and conventions
- Document conventions
- Section 2 Safety information
- Caution signs
- Note signs
- Section 3 Environmental aspects
- Section 4 Unpacking, inspecting and storing
- Storing
- Section 5 Mounting
- Flush mounting
- Mounting procedure for flush mounting
- Mounting procedure for 19" panel rack mounting
- Wall mounting
- Side-by-side 19" rack mounting
- Mounting procedure for side-by-side rack mounting
- Side-by-side flush mounting
- Mounting procedure for side-by-side flush mounting
- Coupling capacitor unit REX061
- Shunt resistor unit REX062
- Section 6 Connecting
- Front side connectors
- Rear side connectors
- Connection examples for high impedance differential protection
- Connecting to protective ground
- Connecting to CT and VT circuits
- Connecting the binary input and output signals
- Making the shield connection
- Making the electrical connection to the rotor and stator injection equipment (REG670 only)
- Connecting injection unit REX060, coupling capacitor unit REX061 and shunt resistor unit REX062
- Connecting and setting voltage inputs
- Making of Ethernet connections
- Connecting remote communication interfaces LDCM
- Installing the serial communication cable for RS485
- Installing the serial communication cable for RS485 SPA/IEC
- Data on RS485 serial communication module cable
- Installing the GPS antenna
- Electrical installation
- Section 7 Checking installation
- Section 8 Removing, repairing and exchanging
- Exchanging the IED
- Section 9 Technical data
- Case with protective cover
- Flush mounting dimensions
- Side-by-side flush mounting dimensions
- Wall mounting dimensions
- Section 10 Glossary
RELION RER670
Table of contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Section 1 Introduction
- Product documentation
- Document revision history
- Related documents
- Document conventions
- IEC 61850 edition 1 / edition 2 mapping
- Section 2 Application
- Main protection functions
- Back-up protection functions
- Control and monitoring functions
- Communication
- Basic IED functions
- Section 3 Configuration
- Description of configuration – transformer protection application in compensated networks
- Description of configuration – transformer protection application in solidly earthed networks
- Description of configuration – line protection application in compensated networks
- Description of configuration – line protection application in solidly earthed networks
- Section 4 Analog inputs
- Setting of the phase reference channel
- Example 1
- Example 3
- inputs for most commonly used CT connections
- Example on how to connect a star connected two-phase CT set to the IED
- Example how to connect single-phase CT to the IED
- Relationships between setting parameter Base Current, CT rated primary current and minimum pickup of a protection IED
- Setting of voltage channels
- Examples on how to connect a two phase-to-earth connected VT to the IED
- Example on how to connect a residually connected IED
- Example of analogue configuration for railway applications
- Configuration example 1
- Configuration example 2
- Configuration example 3
- Section 5 Local HMI
- Display
- LEDs
- Keypad
- Local HMI functionality
- Parameter management
- Front communication
- Low impedance restricted earth fault protection REFPDIF
- Transformer winding, solidly earthed
- CT earthing direction
- Settings
- Setting guidelines
- Elimination of zero sequence currents
- Protections based on the directional criterion
- Application examples
- How to wire the transformer differential protection to the IED using CTs
- Automatic switch onto fault logic ZCVPSOF
- Distance protection, quadrilateral characteristic ZRWPDIS
- Compensated earthing systems
- Solidly earthed systems
- High impedance earthing systems
- Setting examples
- Underimpedance protection for railway transformers ZGTPDIS
- Zone 1 operation
- Catenary Protection
- Wrong phase coupling protection
- Instantaneous phase overcurrent protection 2-phase output PHPIOC
- Two-step directional phase overcurrent protection D2PTOC
- Settings for step 1
- Settings for step 2
- Application
- Two step residual overcurrent protection EF2PTOC
- Settings for each step (x = 1 and 2)
- Common settings
- nd harmonic restrain
- Sensitive directional residual overcurrent and power protection SDEPSDE
- Thermal overload protection, one time constant, Celsius LPTTR
- Setting guideline
- Breaker failure protection CCRWRBRF
- Overcurrent protection with binary release BRPTOC
- Two step undervoltage protection U2RWPTUV
- Two step overvoltage protection O2RWPTOV
- Two step residual overvoltage protection ROV2PTOV
- High impedance earthed systems
- Underfrequency protection SAPTUF
- Current circuit supervision CCSSPVC
- Dead line detection
- Synchrocheck, energizing check, and synchronizing SESRSYN
- Synchrocheck
- Energizing check
- External fuse failure
- Single circuit breaker with single busbar
- Autoreclosing for railway system SMBRREC
- Auto reclosing operation Off and On
- Blocking of the auto recloser
- counter
- Configuration
- Auto recloser settings
- Apparatus control APC
- Bay control QCBAY
- Switch controller SCSWI
- Switches SXCBR/SXSWI
- XLNPROXY
- Reservation function (QCRSV and RESIN)
- Interaction between modules
- Bay control (QCBAY)
- Switch (SXCBR/SXSWI)
- Reservation input (RESIN)
- Configuration guidelines
- Signals from bypass busbar
- Signals from bus-coupler
- Configuration setting
- Interlocking for bus-coupler bay ABC_BC
- Interlocking for transformer bay AB_TRAFO
- Interlocking for bus-section breaker A1A2_BS
- Interlocking for bus-section disconnector A1A2_DC
- Signals in double-breaker arrangement
- Signals in 1 1/2 breaker arrangement
- Interlocking for busbar earthing switch BB_ES
- Interlocking for double CB bay DB
- Interlocking for 1 1/2 CB BH
- Voltage control
- TR1ATCC or TR8ATCC Setting group
- TCMYLTC and TCLYLTC general settings
- Logic rotating switch for function selection and LHMI presentation SLGAPC
- Selector mini switch VSGAPC
- Transformer energizing control XENCPOW
- Scheme communication logic for distance or overcurrent protection ZCPSCH
- Blocking schemes
- Permissive schemes
- Intertrip scheme
- Permissive overreaching scheme
- Weak-end infeed logic
- Current reversal logic
- Current reversal and weak-end infeed logic for residual overcurrent protection ECRWPSCH
- Weak-end infeed
- Tripping logic SMPPTRC
- Lock-out
- Blocking of the function block
- Logic for group alarm WRNCALH
- Configurable logic blocks
- Fixed signal function block FXDSIGN
- Boolean 16 to Integer conversion B16I
- Boolean to integer conversion with logical node representation, 16 bit BTIGAPC
- Integer to Boolean 16 conversion IB16
- Identification
- representation ITBGAPC
- Elapsed time integrator with limit transgression and overflow supervision TEIGAPC
- Comparator for real inputs - REALCOMP
- Setting example
- Measurement
- Zero clamping
- Gas medium supervision SSIMG
- Liquid medium supervision SSIML
- Breaker monitoring SSCBR
- Setting procedure on the IED
- Event function EVENT
- Disturbance report DRPRDRE
- Recording times
- Analog input signals
- Consideration
- Logical signal status report BINSTATREP
- Pulse-counter logic PCFCNT
- Function for energy calculation and demand handling ETPMMTR
- Access point
- Redundant communication
- Merging unit
- Communication protocols
- Receiving data
- IEC/UCA 61850-9-2LE communication protocol
- Specific settings related to the IEC/UCA 61850-9-2LE communication
- Setting examples for IEC/UCA 61850-9-2LE and time synchronization
- IEC 61850 quality expander QUALEXP
- LON communication protocol
- MULTICMDRCV and MULTICMDSND
- IEC 60870-5-103 communication protocol
- Design
- Settings for RS485 and optical serial communication
- Settings from PCM600
- Function and information types
- DNP3 Communication protocol
- Binary signal transfer
- Communication hardware solutions
- Authority status ATHSTAT
- Change lock CHNGLCK
- Denial of service SCHLCCH/RCHLCCH
- IED identifiers TERMINALID
- Measured value expander block RANGE_XP
- Signal matrix for binary outputs SMBO
- Frequency values
- Test mode functionality TESTMODE
- System time
- Process bus IEC/UCA 61850-9-2LE synchronization
- Current transformer requirements
- Conditions
- Fault current
- General current transformer requirements
- Restricted earth fault protection (low impedance differential)
- Current transformer requirements for CTs according to other standards
- Voltage transformer requirements
- SNTP server requirements
- IEC/UCA 61850-9-2LE Merging unit requirements
- Section 23 Glossary
RELION RER670
Table of contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Section 1 Introduction
- Product documentation
- Document revision history
- Related documents
- Document conventions
- IEC 61850 edition 1 / edition 2 mapping
- Section 2 Safety information
- Caution signs
- Section 3 Available functions
- Back-up protection functions
- Control and monitoring functions
- Communication
- Basic IED functions
- Section 4 Starting up
- Checking the power supply
- IED start-up sequence
- Writing an application configuration to the IED
- Checking CT circuits
- Checking VT circuits
- Checking the binary input/output circuits
- Section 5 Configuring the IED and changing settings
- Configuring analog CT inputs
- Section 6 Establishing connection and verifying the SPA/IEC communication
- Verifying the communication
- Fiber optic loop
- Section 7 Establishing connection and verifying the LON communication
- The LON Protocol
- Optical budget calculation for serial communication with LON
- Section 8 Establishing connection and verifying the IEC
- Section 9 Testing IED operation
- Preparing the IED to verify settings
- Activating the test mode
- Connecting the test equipment to the IED
- Releasing the function to be tested
- Verifying analog primary and secondary measurement
- Testing the protection functionality
- Forcing of binary input/output signals for testing
- Enable forcing using TESTMODE function block
- Forcing by using PCM600
- operation
- Undo forcing by using TESTMODE component
- Testing disturbance report
- Event recorder (ER) and Event list (EL)
- Identifying the function to test in the technical reference manual
- Completing the test
- Verifying the restrained protection
- Verifying the differential alarm
- Initiating ZCVPSOF automatically and setting mode to impedance
- Distance protection zone, quadrilateral characteristic ZRWPDIS
- Underimpedance protection for railway transformers ZGTPDIS
- Current protection
- Verifying the settings
- Instantaneous residual overcurrent protection EFRWPIOC
- Two step non-directional earth fault protection
- Verifying the re-trip mode
- Verifying instantaneous back-up trip at CB faulty condition
- Fuse failure supervision FRWSPVC
- function
- Current based delta supervision DELISPVC
- Delta supervision of real input DELSPVC
- Testing the synchronizing function
- Testing the synchrocheck functionality
- Testing the energizing check
- Preparation of the verification
- Verifying the auto recloser
- Checking the auto reclosing conditions
- Secondary test
- Check the activation of the voltage control operation
- Check the undervoltage block function
- Check the overcurrent block function
- Parallel voltage regulation
- Testing permissive underreaching
- Testing blocking scheme
- Current reversal logic
- Testing the directional comparison logic function
- Testing the current reversal logic
- Testing the gas medium supervision for pressure alarm and pressure lockout conditions
- Liquid medium supervision SSIML
- Voltage harmonic monitoring VHMMHAN
- Metering
- Station communication
- Section 11 Commissioning and maintenance of the fault clearing system
- Visual inspection
- Recording
- Measurement of service currents
- Restoring
- Section 12 Troubleshooting
- Fault tracing
- Using front-connected PC
- Diagnosing the IED status via the LHMI hint menu
- Hardware re-configuration
- Repair instruction
- Repair support
- Section 13 Glossary
Related products
Relion 670 seriesRELION REX640RELION 650 SERIESRelion 615 seriesREL 356ReliaGear LV SG E2.2ReliaGear LV SG E4.2ReliaGear LV SG E6.2RED615 ANSISmart Communication CardABB categories
Industrial Equipment
DC Drives
Controller
Relays
Measuring Instruments
Circuit breakers
Battery Charger
Industrial Electrical
Transformer
Switch
manualsdatabase
Your AI-powered manual search engine