Daikin RXS35D2VMB manuals
RXS35D2VMB
Table of contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- safety cautions
- cautions regarding products after repair
- inspection after repair
- using icons
- Part 1 List of Functions
- List of Functions
- Part 2 Specifications
- Specifications
- Heat Pump
- Part 3 Printed Circuit Board Connector Wiring Diagram
- Printed Circuit Board Connector Wiring Diagram
- Outdoor Unit
- Part 4 Function and Control
- Main Functions
- Air Flow Direction Control
- Fan Speed Control for Indoor Units
- Programme Dry Function
- Automatic Operation
- Thermostat Control
- NIGHT SET Mode
- ECONO Mode
- INTELLIGENT EYE
- Inverter POWERFUL Operation
- Other Functions
- Function of Thermistor
- Cooling Only Model
- Control Specification
- Frequency Control
- Controls at Mode Changing / Start-up
- Discharge Pipe Control
- Input Current Control
- Freeze-up Protection Control
- Fan Control
- Defrost Control
- Electronic Expansion Valve Control
- Malfunctions
- Forced Operation Mode
- Facility Setting Jumper (cooling at low outdoor temperature)
- Part 5 System Configuration
- System Configuration
- Instruction
- installation site
- Names of parts
- remote controller
- Preparation before Operation
- AUTO · DRY · COOL · HEAT · FAN Operation
- Adjusting the Air Flow Direction
- POWERFUL Operation
- OUTDOOR UNIT SILENT Operation
- ECONO Operation
- INTELLIGENT EYE Operation
- TIMER Operation
- Care and Cleaning
- air filter
- before a long idle period
- Troubleshooting
- check again
- disposal requirements
- fault diagnosis
- Part 6 Service Diagnosis
- Caution for Diagnosis
- Problem Symptoms and Measures
- Service Check Function
- Indoor Unit PCB Abnormality
- Freeze-up Protection Control or High Pressure Control
- Fan Motor (DC Motor) or Related Abnormality
- Thermistor or Related Abnormality (Indoor Unit)
- Signal Transmission Error (between Indoor and Outdoor Unit)
- Unspecified Voltage (between Indoor and Outdoor Units)
- Outdoor Unit PCB Abnormality
- OL Activation (Compressor Overload)
- Compressor Lock
- DC Fan Lock
- Input Over Current Detection
- Four Way Valve Abnormality
- Discharge Pipe Temperature Control
- High Pressure Control in Cooling
- Compressor System Sensor Abnormality
- Position Sensor Abnormality
- DC Voltage / Current Sensor Abnormality
- Thermistor or Related Abnormality (Outdoor Unit)
- Electrical Box Temperature Rise
- Radiation Fin Temperature Rise
- Output Over Current Detection
- Insufficient Gas
- Over-voltage Detection
- Check
- SiEBE04
- thermistor resistance check
- installation condition check
- outdoor unit fan system check
- power transistor check
- Part 7 Removal Procedure
- Indoor Unit
- Removal of Front Panel
- Removal of Front Grille
- Removal of Horizontal Blades and Vertical Blades
- Removal of Electrical Box
- Removal of PCB
- Removal of Drain Pan Unit
- Removal of Fan Motor
- Removal of Heat Exchanger
- Removal of Fan Rotor
- Removal of Reactor and Partition Plate
- Removal of Sound Blanket
- Removal of Four Way Valve
- Removal of Compressor
- Part 8 Others
- Others
- Jumper Settings
- Part 9 Appendix
- Piping Diagrams
- Outdoor Units
- Wiring Diagrams
RXS35D2VMB
Table of contents
- service manual
- Table of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- about this manual
- Part 1 System Outline
- Table Of Contents
- What Is in This Chapter?
- FCQ35, 50, 60, 71B
- FCQ100, 125, 140D
- FFQ25, 35, 50, 60B
- FBQ35, 50B
- FBQ60, 71B
- FBQ100, 125B
- FHQ35, 50B
- FHQ60, 71B
- FHQ100B
- FHQ125B
- FUQ71B
- FUQ100, 125B
- FAQ71B
- FAQ100B
- FDEQ71, 100B
- FDEQ125B
- specifications
- technical specifications
- Indoor Piping
- Pipe Connection Diameters
- Piping Components
- Part 1
- FCQ35, 50, 60B
- FCQ71, 100, 125B
- FCQ71, 100, 125, 140D
- FBQ35, 50, 60B
- FBQ71B
- FDQ125, 200, 250B
- FHQ35, 50, 60B
- FHQ71, 100, 125B
- FUQ71, 100, 125B
- FDEQ71B
- FDEQ100B
- Part 1
- FCQ100, 125B
- FCQ71, 100, 125 140D
- FBQ35, 50, 60, 71, 100, 125B
- FHQ35, 50, 60, 71, 100, 125B
- FDEQ71, 100, 125B
- FBQ35, 50, 60, 71B & FDEQ71B
- FBQ100, 125B & FDEQ100, 125B
- Part 2
- Simulated Operation Function
- functions of thermistors
- forced operating mode (emergency operation)
- outdoor unit identification function
- simulated operation function
- restart standby
- automatic restart
- using conditions for remote control thermostat
- forced thermostat off
- freeze prevention function
- pmv control
- thermostat control
- drain pump control
- condensation avoidance control
- fan and flap operations
- indoor unit fan control
- Additional Checks for Troubleshooting
- What Is in This Chapter
- troubleshooting
- overview of general problems
- equipment does not operate
- equipment operates but does not provide heating
- equipment discharges white mist
- equipment produces loud noise or shakes
- equipment discharges dust
- swing flap does not operate
- Troubleshooting by LED Indications on the Indoor Unit
- system malfunctions
- Overview of the Indoor Safety Devices
- Malfunction of Transmission between Indoor and Outdoor Unit (U4 or UF)
- Test Run Checks
- Part 4
- how to change the field settings with the wired remote control
- how to change the field settings with the infrared remote control
- Overview of the Field Settings on the Indoor Units
- Overview of the Factory Settings on the Indoor Units
- Setting the Ceiling Height
- Setting the Filter Counter
- main/sub setting when using two remote controls
- setting the centralized group no
- The Field Setting Levels
- General Operation Data
- Table Of Contents
- removal of suction grille
- removal of air filter
- removal of decoration panel
- removal of horizontal blade
- removal of swing motor
- removal of switch box
- removal of pc board
- removal of humidity sensor and air temperature thermistor
- removal of fan motor
- removal of drain pan, drain pump, float switch
- removal of heat exchanger temperature thermistor
- 1.12 FFQ25, 50, 60B
- Table Of Contents
- removal of horizontal vane
- removal of fan rotor and fan motor
- removal of drain pan
- removal of drain pump
- installation of drain pump
- replacement of heat exchanger thermistor
- replacement of heat exchanger
- replacement of pc board
- replacement of receiver section of infrared remote control
- removal of air filter and suction grille
- removal of electrical parts and pc boards
- removal of fan bearing
- removal of bottom panel and drain pan
- removal of fan
- removal of air flow control blade
- removal of front grille
- removal of electrical box
- removal of heat exchanger
- removal of electrical parts box
- removal of swing louvre unit
- removal of fan rotor
- Table Of Contents
- Table Of Contents
- Table Of Contents
RXS35D2VMB
Table of contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- safety cautions
- cautions regarding products after repair
- inspection after repair
- using icons
- Part 1 List of Functions
- list of functions
- Part 2 Specifications
- Specifications
- Heat Pump
- Part 3 Printed Circuit Board Connector Wiring Diagram
- printed circuit board connector wiring diagram
- Outdoor Unit
- function and control
- main functions
- air flow direction control
- fan speed control for indoor units
- programme dry function
- automatic operation
- thermostat control
- night set mode
- econo mode
- intelligent eye
- inverter powerful operation
- other functions
- function of thermistor
- cooling only model
- control specification
- frequency control
- controls at mode changing / start-up
- Discharge Pipe Control
- input current control
- freeze-up protection control
- fan control
- defrost control
- electronic expansion valve control
- Malfunctions
- forced operation mode
- Facility Setting Jumper (cooling at low outdoor temperature)
- Part 5 System Configuration
- System Configuration
- safety precautions
- installation site
- names of parts
- remote control
- preparation before operation
- to set the clock
- auto · dry · cool · heat · fan operation
- to change the air flow rate setting
- adjusting the air flow direction
- powerful operation
- outdoor unit silent operation
- econo operation
- intelligent eye operation
- timer operation
- to use on timer operation
- care and cleaning
- air filter
- before a long idle period
- Troubleshooting
- check again
- call the service shop immediately
- fault diagnosis
- Part 6 Service Diagnosis
- caution for diagnosis
- problem symptoms and measures
- service check function
- error codes and description
- indoor unit pcb abnormality
- freeze-up protection control or high pressure control
- fan motor (dc motor) or related abnormality
- thermistor or related abnormality (indoor unit)
- Signal Transmission Error (between Indoor and Outdoor Unit)
- unspecified voltage (between indoor and outdoor units)
- outdoor unit pcb abnormality
- ol activation (compressor overload)
- compressor lock
- dc fan lock
- input over current detection
- four way valve abnormality
- discharge pipe temperature control
- high pressure control in cooling
- compressor system sensor abnormality
- position sensor abnormality
- dc voltage / current sensor abnormality
- thermistor or related abnormality (outdoor unit)
- electrical box temperature rise
- radiation fin temperature rise
- output over current detection
- insufficient gas
- over-voltage detection
- how to check
- four way valve performance check
- thermistor resistance check
- installation condition check
- outdoor unit fan system check
- power transistor check
- Part 7 Removal Procedure
- removal of air filter
- removal of front panel
- removal of front grille
- removal of horizontal blades and vertical blades
- Removal of Electrical Box
- Removal of PCB
- removal of drain pan unit
- removal of fan motor
- removal of heat exchanger
- removal of fan rotor
- removal of panels and fan motor
- removal of reactor and partition plate
- removal of sound blanket
- removal of four way valve
- removal of compressor
- Part 8 Others
- test run from the remote controller
- jumper settings
- Part 9 Appendix
- Piping Diagrams
- Outdoor Units
- wiring diagrams
- Table Of Contents
RXS35D2VMB
Table of contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- safety cautions
- cautions regarding products after repair
- inspection after repair
- using icons
- Part 1 List of Functions
- List of Functions
- Part 2 Specifications
- Specifications
- Heat Pump
- Part 3 Printed Circuit Board Connector Wiring Diagram
- Printed Circuit Board Connector Wiring Diagram
- Outdoor Unit
- Part 4 Function and Control
- Main Functions
- Flap Control
- Air Flow Selection
- Fan Speed Control for Indoor Units
- Programme Dry Function
- Automatic Operation
- Thermostat Control
- NIGHT SET Mode
- HOME LEAVE Operation
- Inverter POWERFUL Operation
- Other Functions
- Function of Thermistor
- Cooling Only Model
- Control Specification
- Frequency Control
- Controls at Mode Changing / Start-up
- Discharge Pipe Control
- Input Current Control
- Freeze-up Protection Control
- Fan Control
- Defrost Control
- Electronic Expansion Valve Control
- Malfunctions
- Forced Operation Mode
- Facility Setting Jumper (cooling at low outdoor temperature)
- Part 5 System Configuration
- System Configuration
- Instruction
- installation site
- Names of parts
- remote controller
- Preparation before Operation
- AUTO · DRY · COOL · HEAT · FAN Operation
- Adjusting the Air Flow Direction
- POWERFUL Operation
- OUTDOOR UNIT SILENT Operation
- TIMER Operation
- Care and Cleaning
- air filter
- before a long idle period
- Troubleshooting
- check again
- disposal requirements
- fault diagnosis
- Part 6 Service Diagnosis
- Caution for Diagnosis
- Problem Symptoms and Measures
- Service Check Function
- Indoor Unit PCB Abnormality
- Fan Motor (DC Motor) or Related Abnormality
- Thermistor or Related Abnormality (Indoor Unit)
- Signal Transmission Error (between Indoor and Outdoor Unit)
- between indoor and outdoor units
- Outdoor Unit PCB Abnormality
- OL Activation (Compressor Overload)
- Compressor Lock
- DC Fan Lock
- Input Over Current Detection
- Four Way Valve Abnormality
- Discharge Pipe Temperature Control
- High Pressure Control in Cooling
- Compressor System Sensor Abnormality
- Position Sensor Abnormality
- DC Voltage / Current Sensor Abnormality
- Thermistor or Related Abnormality (Outdoor Unit)
- Electrical Box Temperature Rise
- Radiation Fin Temperature Rise
- Output Over Current Detection
- Insufficient Gas
- Over-voltage Detection
- Check
- electronic expansion valve check
- four way valve performance check
- thermistor resistance check
- installation condition check
- outdoor unit fan system check
- power transistor check
- Part 7 Removal Procedure
- Indoor Unit
- heat exchanger
- Removal of Electrical Box
- Removal of Sound Blanket
- Removal of Compressor
- removal of pcb
- Part 8 Others
- Others
- Jumper Settings
- Part 9 Appendix
- Piping Diagrams
- Outdoor Units
- Wiring Diagrams
RXS35D2VMB
Table of contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- safety cautions
- cautions regarding products after repair
- inspection after repair
- using icons
- part 1 list of functions
- list of functions
- Part 2 Specifications
- Specifications
- Heat Pump
- Part 3 Printed Circuit Board Connector Wiring Diagram
- printed circuit board connector wiring diagram
- Outdoor Unit
- Part 4 Function and Control
- main functions
- Auto-Swing
- fan speed control for indoor units
- programme dry function
- automatic operation
- thermostat control
- night set mode
- HOME LEAVE Operation
- inverter powerful operation
- other functions
- function of thermistor
- cooling only model
- control specification
- frequency control
- Controls at Mode Changing / Start-up
- compressor protection function
- input current control
- Freeze-up Protection Control
- fan control
- defrost control
- electronic expansion valve control
- Malfunctions
- forced operation mode
- Facility Setting Jumper (cooling at low outdoor temperature)
- Part 5 System Configuration
- System Configuration
- Instruction
- installation site
- Names of parts
- remote controller
- Preparation before Operation
- AUTO · DRY · COOL · HEAT · FAN Operation
- Adjusting the Air Flow Direction
- POWERFUL Operation
- OUTDOOR UNIT SILENT Operation
- TIMER Operation
- Care and Cleaning
- air filter
- before a long idle period
- troubleshooting
- check again
- disposal requirements
- fault diagnosis
- Part 6 Service Diagnosis
- caution for diagnosis
- problem symptoms and measures
- service check function
- indoor unit pcb abnormality
- Fan Motor (AC Motor) or Related Abnormality
- Thermistor or Related Abnormality (Indoor Unit)
- Signal Transmission Error (between Indoor and Outdoor Unit)
- between indoor and outdoor units
- outdoor unit pcb abnormality
- OL Activation (Compressor Overload)
- compressor lock
- dc fan lock
- input over current detection
- four way valve abnormality
- discharge pipe temperature control
- high pressure control in cooling
- compressor system sensor abnormality
- position sensor abnormality
- DC Voltage / Current Sensor Abnormality
- Thermistor or Related Abnormality (Outdoor Unit)
- electrical box temperature rise
- radiation fin temperature rise
- output over current detection
- insufficient gas
- Over-voltage Detection
- how to check
- four way valve performance check
- installation condition check
- outdoor unit fan system check
- power transistor check
- hall ic check
- Part 7 Removal Procedure
- Indoor Unit
- removal of the front panel
- removal of the horizontal blade
- Removal of the Signal Receiver Unit / Swing Motor
- removal of the discharge grille
- removal of the drain pan
- Removal of the Electrical Box / PCB
- removal of the heat exchanger
- removal of panels and fan motor
- removal of electrical box
- removal of sound blanket
- removal of compressor
- removal of pcb
- Part 8 Others
- test run from the remote controller
- jumper settings
- Part 9 Appendix
- piping diagrams
- Outdoor Units
- Wiring Diagrams