IDEC SmartRelay Series manuals
SmartRelay Series
Table of contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Getting started with IDEC SmartRelay
- IDEC SmartRelay installation and wiring
- Setup of the modular IDEC SmartRelay
- Setup with different voltage classes
- Installing/removing IDEC SmartRelay
- Wall-mounting
- Wiring the IDEC SmartRelay
- Connecting IDEC SmartRelay inputs
- Connecting outputs
- Switching on the IDEC SmartRelay /Power On
- Programming IDEC SmartRelay
- Connectors
- Blocks and block numbers
- The way to IDEC SmartRelay, starting with the circuit diagram
- The 4 golden rules for the operation of IDEC SmartRelay
- Overview of the IDEC SmartRelay menus
- Writing and starting the circuit program
- Circuit program input
- Assigning a circuit program name
- Password
- Switching IDEC SmartRelay to RUN mode
- Second circuit program
- Deleting a block
- Deleting block groups
- Correcting typing errors
- Deleting the circuit program
- Summertime/wintertime conversion
- Synchronization
- Memory space and circuit dimensions
- IDEC SmartRelay functions
- Constants and connectors - Co
- Basic functions list - GF
- AND with Edge Detection
- NAND (NOT AND)
- NAND with Edge Detection
- NOR (NOT OR)
- XOR (exclusive OR)
- Basics on special functions
- Designation of the inputs
- Time response
- Backup of the real-time clock
- Parameter protection
- Special functions list - SF
- On-delay
- Off-delay
- On-/Off-delay
- Retentive on-delay
- Interval time-delay relay / Pulse output
- Edge-triggered interval time-delay relay
- Asynchronous pulse generator
- Random generator
- Stairwell Light Switch
- Dual-function switch
- Seven-day time switch
- Twelve-month time switch
- Up/down counter
- Operating hours counter
- Frequency trigger
- Analog trigger
- Analog differential trigger
- Analog comparator
- Analog value monitoring
- Latching relay
- Current impulse relay
- Message texts
- Softkey
- Shift register
- Configuring IDEC SmartRelay
- Selecting parameter assignment mode
- Parameters
- Selecting the parameters
- Modifying parameters
- Setting the time-of-day and date (FL1C-12RC...)
- Security function (CopyProtect)
- Inserting and removing the memory cartridge (card)
- Copying data from the IDEC SmartRelay to the memory cartridge (card)
- Copying data from the memory cartridge (card) to IDEC SmartRelay
- IDEC SmartRelay software
- Connecting the IDEC SmartRelay to a PC
- Applications
- Stairway or corridor lighting
- Lighting system with IDEC SmartRelay
- Special features and expansion options
- Automatic door
- Conventional solution
- Air-conditioning system
- Advantages of using IDEC SmartRelay
- Factory door
- Previous solution
- Extended IDEC SmartRelay solution
- Centralized control and monitoring of several factory doors
- Requirements for a gate control system
- Luminous rows
- Luminous row control system with FL1C-H12RCC
- Service water pump
- Requirements for a control system of a service water pump
- Service water pump system with FL1C-H12RCC
- Special features and expansions
- Benefits of IDEC SmartRelay
- A Technical data
- A.2 Technical data: FL1C-...12RCC and FL1B-M08C2R2
- A.3 Technical data: FL1C-H12SND and FL1B-M08B1S2
- A.4 Technical data: FL1C-...12RCA and FL1B-M08D2R2
- A.5 Technical data: FL1C-...12RCE and FL1B-M08B2R2
- A.6 Switching capacity and service life of the relay outputs
- A.7 Technical data: FL1B-J2B2
- B Determining the cycle time
- C IDEC SmartRelay without display
- D IDEC SmartRelay menu structure
- E Type Numbers
- Index
Related products
SmartRelay FL1D SeriesSmartRelay FL1B-J2B2MicroSmart SeriesSmartRelay FL1C-B12RCESmartRelay FL1C-B12RCASmartRelay FL1C-H12SNDSmartRelay FL1C-H12RCCSmartRelay FL1C-H12RCASmartRelay FL1C-H12RCESmartRelay FL1D-B12RCAIDEC categories
Switch
Controller
Control Unit
Relays
Power Supply
Computer Hardware
Lighting Equipment
Other
Security Sensors
Recording Equipment
manualsdatabase
Your AI-powered manual search engine