3ware Escalade Storage Switch User Guide138 www.3ware.com3 Physically remove the failed drive and replace it with a newdrive.4 Click on the check box of the new drive.5 Click the Add Drive button.6 Click on the check boxes of the members of the array to berebuilt. This should include the new drive added in step 3.7 Click the Rebuild Array button. The rebuild process will run inthe background and an event notification will be sent when it iscompleted.Selecting Force ContinueSelecting the Force Continue on Source Errors check box prior torebuilding the array ensures rebuilds are not terminated if ECCerrors are detected on the source disk. By default, this function isdisabled.Scheduling rebuilds and media scansThe 3DM Configuration display allows routine maintenance ofstorage media by scheduling array rebuilds or initializations, arrayverifications, and media scans. The day, time and duration of eachscheduled occurrence can be specified using pull-down menus.When finished, be sure to click on the Save Schedule button toconfirm the entries.The Help display (see Figure 57) provides direct links to 3ware’swebsite and online help documents.