3ware Disk Array Configuration Utilitywww.3ware.com 438 Press F8 to rebuild. The rebuild confirmation screen will be dis-played (see Figure 20).Figure 20. Rebuild Confirmation Display9 Enter Y to update configurations and exit.Auto rebuild of a mirrored or RAID 5 arrayIf a hot spare is specified and the mirrored or RAID 5 arraydegrades, an event notification is generated and the hot sparedynamically replaces the failed drive in the array without user inter-vention. Rebuild will automatically be launched as a backgroundprocess and an event notification will notify the user when therebuild process is complete.3 w a r e D i s k A r r a y C o n f i g u r a t i o nRestore Initial ValuesF6 CancelEsc DoneF8Creating or destroying arrays will destroy all existing data on theirmember disk drives. Using a drive for a rebuild will overwrite data onthat drive.Data on the following drives will be destroyed.Port 3 QUANTUM FIREBALL LM30Update configuration and exit? [Y/N]