Chapter 3. Legacy CLI Syntax Reference110 3ware 9000 Series Serial ATA Controller CLI GuideSyntaxalarmsalarms c [c ...]Warning!3ware does not recommend installing both 3DM and CLI.Conflicts may occur. If both are installed, alarms will be capturedonly by 3DM.Warning!3DM and CLI handle alarms differently. When using CLI with the7/8000 series, save the alarm data immediately after viewing it.Once the alarms are viewed using CLI, they cannot be viewedagain.With the 9000 series, the alarms can be viewed multiple times with the CLI,but will be lost following a reboot. At this time there is no CLI option to clearthe alarms log.alarms [cid ...]This command displays all available alarms on a single controller, multiplecontrollers, or on all controllers. Invoked without cid, displays alarmsassociated with all detected controllers.Note: A listing of AEN codes can be found in the “Troubleshooting:Problems and Solutions” section of 3ware 9000 Series Serial ATA RAIDController User Guide.Typical output looks like:tw_cli> alarmsCtl Date Severity Message--------------------------------------------------c0 - - ERROR: Unit degraded: Unit #0c1 [Fri Nov 28 04:26:31 2003] ERROR (0x04:0x0002): Degraded unit detected: unit=0, port=2c1 [Fri Nov 28 06:13:54 2003] INFO (0x04:0x000B): Rebuild started: unit=0c1 [Fri Nov 28 06:30:35 2003] INFO (0x04:0x003B): Background rebuild paused: unit=0c1 [Fri Nov 28 06:33:00 2003] ERROR (0x04:0x0002): Degraded unit detected: unit=0, port=0c1 [Fri Nov 28 06:33:04 2003] ERROR (0x04:0x0002): Degraded unit detected: unit=0, port=4c1 [Fri Nov 28 06:33:46 2003] INFO (0x04:0x000B): Rebuild started: unit=0c1 [Fri Nov 28 06:37:58 2003] INFO (0x04:0x000B): Rebuild started: unit=0c1 [Fri Nov 28 07:51:34 2003] INFO (0x04:0x0005): Background rebuild done: unit=0c1 [Fri Nov 28 07:59:43 2003] INFO (0x04:0x0005): Background rebuild done: unit=0c1 [Mon Dec 1 02:26:12 2003] ERROR (0x04:0x0002): Degraded unit detected: unit=0, port=3