Chapter 2. Primary CLI Syntax Reference74 3ware 9000 Series Serial ATA Controller CLI Guide/cx/bbu show lasttestThis command shows the date the battery capacity was last measured. If thebattery capacity test has never been run, then 'xx-xxx-xxxx' will be displayed.Note: The estimated BBU capacity hours displayed is based on themeasurement taken during the last test. If you have not run the BBU testcommand for some time, this number can be misleading. For informationabout running a test, see “/cx/bbu test [quiet]” on page 75./cx/bbu show voltThis command shows the voltage status of the battery. The status can be OK,HIGH, LOW, TOO-HIGH, and TOO-LOW. The HIGH and LOW are inwarning range. TOO-HIGH and TOO-LOW are out of the operating rangeand indicate that it is time to replace the battery. (Contact AMCC to obtain areplacement battery.)/cx/bbu show tempThis command shows the temperature status of the battery. The status can beOK, HIGH, LOW, TOO-HIGH, and TOO-LOW. The HIGH and LOW are inwarning range. TOO-HIGH and TOO-LOW are out of the operating rangeand indicate that it may be time to replace the battery. (Contact AMCC toobtain a replacement battery.)/cx/bbu show capThis command shows the battery capacity in hours.A value of '0 hours' will be displayed if the battery capacity test has neverbeen run.Note: The estimated BBU capacity hours displayed is based on themeasurement taken during the last test. If you have not run the BBU testcommand for some time, this number can be misleading. You can use thecommand /cx/bbu show lasttest to check the date of the last test. Forinformation about running a test, see “/cx/bbu test [quiet]” on page 75./cx/bbu show serialThis command shows the BBU serial number./cx/bbu show fwThis command shows the BBU firmware version number.